Respiratory Self-Gating with 3D-Translation Compensation for Whole-Heart Coronary MRA
نویسندگان
چکیده
Introduction: Whole-heart coronary MRA (CMRA) [1] has been gaining increasing acceptance with improved visible vessel length and ease-of-use. However, it necessitates free-breathing imaging and thereby accurate respiratory motion detection. Conventional diaphragmatic navigator (NAV) suffers from indirect measurement of heart position. A newly proposed respiratory self-gating (RSG) method [2,3] can improve the accuracy but is still limited to 1D translation detection. Inaccurate or incomplete motion detection prohibits wide respiratory gating windows (GW) and results in a long scan time, which increases both patient discomfort and the susceptibility to respiratory motion drifting. This study aimed to develop a new RSG technique capable of direct measurement of heart translation in 3D (3D RSG) and evaluate its effectiveness in free-breathing whole-heart CMRA. Theory & Methods: It has been demonstrated by dual-projection RSG (DP-RSG) that surrounding chest wall signals can be eliminated by averaging two superior-inferior (SI) projections with properly designed anterior-posterior (AP) dephasing [3]. An SI heart projection could be generated enabling accurate detection of SI heart motion. If an additional dephasing gradient is applied along a transverse axis for acquisition of this heart projection, heart translation along this direction induces a phase shift in the heart projection proportional to the amount of the corresponding translation. Therefore, it is feasible to detect transverse heart motion by adding motion-encoding (ME) gradients along AP and leftright (LR) directions. As illustrated in Fig. 1, 3D RSG acquisition is comprised of collection of 3 heart projections in 3 pairs of gradient echo RF cycles, corresponding to motion detection along SI, AP and LR. Acquisition of the first SI projection is identical to DP-RSG. The same acquisition was repeated with a nonzero ME gradient applied along AP for the 2nd projection and along LR for the 3rd projection. For motion detection, each pair of RSG signals is average to reconstruct a heart projection without chest wall contamination. Next, profile and phase shifts in the 1st projection with regard to a reference projection at end-expiration are detected, corresponding to SI heart translation and phase shift induced by background gradients (e.g. coil sensitivity). This background phase shift was then removed from the phase shifts calculated in the 2nd and 3rd projections to estimate phase shifts induced by AP and LR heart motion, respectively, which were divided by the strength of ME gradient to estimate transverse motion components. 3D RSG was implemented by inserting the acquisition described above after NAV echo in each heartbeat in a conventional 3D TrueFISP sequence with ECG-triggering and NAVgating. 9 healthy volunteers were imaged using this new sequence on a 1.5T Siemens Avanto system. Typical parameters for coronary imaging included: 320×240 mm FOV; 60 slices interpolated to 120 with 1.0 mm thickness; 1.0×1.1 mm in-plane spatial resolution; 38 lines/segment; 90o flip angle; TE/TR = 1.87/3.74 ms. 3D RSG data were acquired from a sagittal whole-heart slice with 10o flip angle. Based on our simulations, a 5o/mm gradient was used for ME to achieve an optimal compromise between sensitivity to transverse motion and SNR. A GW of ±4.5 mm was used for NAV gating. Respiratory motion during the scan was compensated offline using 3 methods: 1D SI correction based on 1) NAV motion detection; 2) only the SI component of 3D RSG; 3) 3D correction based on 3D RSG motion detection. Qualitative comparison with regard to coronary artery delineation (0-4; 0:worst, 4:best) was performed to assess the effectiveness of different motion correction methods.
منابع مشابه
Free-breathing 3D whole-heart coronary mra using respiratory motion-resolved sparse reconstruction
Background Navigator gating is commonly used to minimize respiratory motion in free-breathing whole-heart coronary MRA [1]. However, lengthy and unpredictable acquisition times remain a drawback. Respiratory self-navigation (SN) [2-3], conversely, enables 100% scan efficiency, but performs motion correction over a broad range of respiratory displacements, which can result in image artifacts. He...
متن کاملSelf-guided retrospective motion correction (SEGMO) for free-breathing whole-heart coronary MRA with 100% acquisition efficiency
Background Free-breathing whole heart coronary MRA uses diaphragm navigator to gate data acquisition, which suffers from the need for time-consuming and exquisite positioning, prolonged scan time due to low gating efficiency, and inaccuracy in motion detection. In this work, a respiratory motion correction scheme is proposed with an affine motion model for accurate estimation of respiratory mot...
متن کاملProspective Heart Tracking for Respiratory Motion Compensation in Whole-heart Magnetic Resonance Angiography
Background Electrocardiogram and respiratory navigator (NAV)gated 3D whole-heart magnetic resonance angiography (MRA) acquired with an intravascular gadolinium-based contrast agent and a non-selective inversion recovery (IR) pulse to null the myocardial signal generates a highresolution anatomic dataset allowing for a comprehensive evaluation of intra-cardiac, coronary, and vascular abnormaliti...
متن کاملWhole-Heart Coronary MRA
Background MRI was first reported to visualize the ostia of the coronary arteries in the late 1980’s (1, 2). Tremendous progress has been made in coronary MRA ever since. One of the milestones was the acquisition of k-space data in a segmented mode (3, 4), allowing collection of an entire data set within multiple heartbeats. Early coronary MRA studies used two-dimensional (2D) technique to acqu...
متن کاملThree-dimensional Whole-Heart Cine MRI using Prospective Self-Gating for Compensation of Cardiac and Respiratory Motion
Introduction: Two-dimensional (2D) breath-hold and ECG-triggered cine MRI is frequently used to assess cardiac function. However this technique requires cooperation from the patient, and the MR acquisition has to be synchronized with the cardiac cycle using ECG. To control respiratory motion, the subject has to perform breath-holds or the position of the diaphragm has to be tracked using a resp...