The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

ثبت نشده
چکیده

Determination of the radionuclide iodine 129 using ICP-MS has been improved by the use of an Octopole Reaction System (ORS) ICP-MS, operated in oxygen cell mode. Oxygen reaction gas removes the background signal at m/z 129, which is due to the presence of Xe as an impurity in the Ar plasma gas and to the polyatomic ion IH2. NIST SRM standards with different 129I/127I ratios and at multiple concentrations were successfully measured, and a 129I detection limit of 1.1 ppt was obtained. No sample preparation is required for aqueous samples and the method is capable of high sample throughput. The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Determination of the radionuclide iodine 129 using ICP-MS has been improved by the use of an Octopole Reaction System (ORS) ICP-MS, operated in oxygen cell mode. Oxygen reaction gas removes the background signal at m/z 129, which is due to the presence of Xe as an impurity in the Ar plasma gas and to the polyatomic ion IH2. NIST SRM standards with different 129I/127I ratios and at multiple conc...

متن کامل

Determination of I/I isotope ratios in liquid solutions and environmental soil samples by ICP-MS with hexapole collision cell

The determination of I in environmental samples at ultratrace levels is very difficult by ICP-MS due to a high noise caused by Xe impurities in argon plasma gas (interference of Xe), possible IH2 1 interference and an insufficient abundance ratio sensitivity of the ICP mass spectrometer for I/I isotope ratio measurement. A sensitive, powerful and fast analytical technique for iodine isotope rat...

متن کامل

Determination of iopromide in environmental waters by ion chromatography - ICP - MS

The determination of iopromide in environmental waters has been accomplished using an Agilent 7700x ICP-MS coupled to an Agilent 1260 LC. The use of High Matrix Introduction (HMI) technology allows for prolonged operation with a sodium hydroxide (NaOH) eluent, and the Octopole Reaction System (ORS3) in helium gas mode reduces polyatomic interferences on iodine (m/z 127). Determination of ioprom...

متن کامل

Determination of Chromium, Selenium, and Molybdenum in Nutritional Products by ICP-MS Authors

An ICP-MS validated method for the rapid determination of chromium (Cr), selenium (Se), and molybdenum (Mo) in infant formula and adult nutritional products was successfully transferred from the Agilent 7500cx ICP-MS to the Agilent 7700x ICP-MS, and from lab 1 to lab 2, respectively. The key advantage of the method is that all samples can be analyzed using a single-cell gas mode (helium mode) t...

متن کامل

State-of-the-art in inorganic mass spectrometry for analysis of high-purity materials

Inorganic mass spectrometric methods are widely used for the multielemental determination of elements at the trace and ultratrace level in high-purity materials (e.g., conducting, semiconducting and nonconducting solid samples, high-purity water, organic solutions and solvents). Inductively coupled plasma mass spectrometry (ICP-MS), laser ablation inductively coupled plasma mass spectrometry (L...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013