CAIPIRINHA-accelerated 2D bSSFP imaging with improved banding behavior using Gradient-Controlled Local Larmor Frequency (GC-LOLA)
نویسندگان
چکیده
Background Cardiac MRI often requires a careful trade-off between SNR, spatio-temporal resolution and slice coverage. Providing fast acquisitions, high SNR and flow/motion robustness, bSSFP has become the dominant sequence. Drawbacks are high SAR levels and sensitivity to B0 inhomogeneities. For improving slice coverage, MSCAIPIRINHA [1] has emerged as a standard method. By simultaneously scanning multiple slices, it provides acceleration in slice direction with minimal SNR penalty. When combining MS-CAIPIRINHA with bSSFP, the sequence steady-state and contrast have to be maintained. Two methods are available: The first [2] employs RFbased multi-slice encoding [1], generating slice-specific shifts in the bSSFP pass-band structure effectively reducing the off-resonance robustness by a factor of two. The second [3] applies balanced gradient encoding during readout, potentially increasing the sensitivity to eddy currents for small inter-slice distances because encoding changes from excitation to excitation.
منابع مشابه
Highly Accelerated SSFP Imaging with Controlled Aliasing in Parallel Imaging and integrated-SSFP (CAIPI-iSSFP)
Purpose To develop a novel combination of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) with integrated SSFP (CAIPI-iSSFP) for accelerated SSFP imaging without banding artifacts at 3T. Materials and Methods CAIPI-iSSFP was developed by adding a dephasing gradient to the balanced SSFP (bSSFP) pulse sequence with a gradient area that results in 2π dephasing...
متن کاملBanding Artifact Reduction in 2D CINE Balanced SSFP at 3.0 T Using Phase-Cycling and k-t BLAST
Introduction Balanced steady-state free precession (bSSFP) offers excellent signal-to-noise ratio (SNR) and consistent blood/myocardium contrast which renders 2D CINE bSSFP an ideal clinical choice for LV function assessment [1] at 1.5 T. bSSFP imaging remains challenging at 3.0 T due to its sensitivity to adverse off-resonance effects induced by strong field inhomogeneities at the heart-lung i...
متن کاملStrategies for Improved 3D Small-Tip Fast Recovery (STFR) Imaging
Introduction: Small tip fast recovery (STFR) imaging has been proposed recently as a potential alternative to balanced steady state free precession (bSSFP). STFR relies on a tailored “tip-up” RF pulse (Fig. 1(a)) to achieve comparable signal level and image contrast as bSSFP, but with reduced banding artifacts [1]. 2D STFR imaging can use fast 2D tailored pulses (e.g., spiral) in combination wi...
متن کاملJoint Reconstruction of Phase-Cycled Balanced SSFP with Constrained Parallel Imaging
Balanced SSFP is an SNR-e cient sequence with unique T /T contrast, but su ers from banding artifacts due to B sensitivity. These artifacts can be mitigated through RF phasecycling at a cost of signi cant increase in scan time. Here, we propose Joint L1-SPIRiT to jointly reconstruct highly accelerated/undersampled phase-cycled images and convert the di erent banding artifacts of these images in...
متن کاملSmall-tip Fast Recovery (STFR) imaging Using Spectrally Tailored Pulse
Introduction: Small tip fast recovery (STFR) imaging has been proposed recently as a potential alternative to balanced steady state free precession (bSSFP) [1, 2]. STFR relies on a tailored “tip-up” RF pulse (Fig. 1(a)) to achieve comparable signal level and image contrast as bSSFP, but with reduced banding artifacts. Previous STFR implementations used 2D or 3D pulses spatially tailored to the ...