Measurement of myocardial blood flow by ultrafast computed tomography.
نویسندگان
چکیده
Myocardial blood flow was analyzed by radioisotope-labeled microspheres and ultrafast computed tomography (CT) in 16 closed-chest, anesthetized dogs. The first set of 10 dogs had CT and microsphere measurements before and after chromonar-induced increases in myocardial blood flow. A second set of six dogs had flows measured at control and during temporary reductions in regional flow produced by balloon cuff occlusion of the left anterior descending coronary artery. All dogs had four-slice, 20-instance CT scans after injection of a medium bolus (0.35 ml/kg) of contrast medium into a femoral vein simultaneous with injection of microspheres into the left atrium. CT myocardial flow was calculated as the change in myocardial CT numbers divided by the area from a blood pool time-density curve. A wide range of myocardial blood flows was produced as determined by microspheres (0 to 6.7 ml/min/g). Global flow of the first set of dogs was shown to have excellent correlation (r = .95, n = 17) for a limited range (.4 less than X less than 1.4 ml/min/g) of flows. Regional flows of these measurements demonstrated less correlation (r = .63, n = 110) but extended the range of flow to 1.7 ml/min/g. At higher flows (greater than 2.5 ml/min/g) the correlation for global and regional flows was not significantly different than zero. Regional ischemic flow correlation extended the linear range of flow to 0 ml/min/g (r = .62, n = 17). These results show that CT can measure myocardial blood flow over a limited but clinically relevant range of flows defined as slightly above normal to ischemic. These results indicate that another preparation of CT flow measurement must be sought for quantification of myocardial perfusion values significantly above normal.
منابع مشابه
Measurement of regional cerebral blood flow using ultrafast computed tomography. Theoretical aspects.
Theoretical and practical limitations have prevented the measurement of regional cerebral blood flow using dynamic x-ray computed tomography. Development of the ultrafast computed tomography scanner has made it possible to overcome the practical limitations and measure changes in contrast concentration in the brain with excellent time and spatial resolution. By applying modifications of indicat...
متن کاملDIAGNOSTIC METHODS RADIOLOGY Measurement of myocardial blood flow by ultrafast computed tomography
Myocardial blood flow was analyzed by radioisotope-labeled microspheres and ultrafast computed tomography (CT) in 16 closed-chest, anesthetized dogs. The first set of 10 dogs had CT and microsphere measurements before and after chromonar-induced increases in myocardial blood flow. A second set of six dogs had flows measured at control and during temporary reductions in regional flow produced by...
متن کاملMeasurement of regional cerebral blood flow in the dog using ultrafast computed tomography. Experimental validation.
The applicability, feasibility, reproducibility, and accuracy of the method of measuring regional cerebral blood flow using ultrafast computed tomography were evaluated in 25 dogs under varying physiological and pathophysiological conditions. Regional cerebral blood flow values were 75.6 +/- 29.4 ml/100 g/min (mean +/- standard deviation) for the hemisphere, 68.4 +/- 28.2 ml/100 g/min for the b...
متن کاملEffect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET
Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...
متن کاملMyocardial perfusion in humans: what can we measure?
Though angina suggests myocardial ischaemia, this symptom is poorly related to the extent, severity, or site of impaired myocardial perfusion. Electrocardiography during graded exercise is commonly used as a clinical tool to assess the extent and site of ischaemia but it is a poor guide. Myocardial oxygen extraction is almost maximal in the resting mammalian heart, an obligatory aerobic organ. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 76 6 شماره
صفحات -
تاریخ انتشار 1987