BACKGROUND Controversies have been observed among network meta-analyses comparing biodegradable polymer drug-eluting stents (BP-DES) with durable polymer drug-eluting stents (DP-DES). We aimed to compare the adverse cardiovascular events associated with BP-DES and durable polymer everolimus-eluting stents (DP-EES) using a large number of patients obtained from randomized controlled trials (RCTs). METHODS Electronic databases were searched for randomized trials comparing BP-DES with DP-EES. Adverse cardiovascular outcomes observed between 6 months and 3 years were considered as the clinical endpoints in this analysis. Odds ratios (ORs) with 95% confidence intervals (CIs) were calculated and the pooled analyses were performed with RevMan 5.3 software. All authors had full access to the data, and they have read and agreed to the manuscript as written. RESULTS Ten trials involving a total number of 13,218 patients (7451 patients treated by BP-DES and 5767 patients treated by DP-EES) were included. No significant difference was observed when analyzing mortality and myocardial infarction between BP-DES and DP-EES with OR 1.08, 95% CI 0.87-1.34, P = .47 and OR 1.04, 95% CI 0.84-1.28, P = .72 respectively. Target vessel revascularization, target lesion revascularization, major adverse cardiac events, and stroke were also not significantly different with OR 1.11, 95% CI 0.92-1.33, P = .28; OR 1.11, 95% CI 0.94-1.33, P = .22; OR 1.12, 95% CI 0.99-1.27; P = .07; and OR 1.13, 95% CI 0.69-1.84; P = .62 respectively. In addition, total stent thrombosis (ST) was similarly reported between BP-DES and DP-EES with OR 0.85, 95% CI 0.59-1.21; P = .37. However, even if BP-DES were associated with a higher rate of definite ST with OR 1.69, 95% CI 0.92-3.08, P = .09 and DP-EES were associated with a higher rate of probable ST with OR 0.67, 95% CI 0.38-1.17, P = .16, these results were not statistically significant. CONCLUSIONS Between 6 months and 3 years, BP-DES were similar in terms of cardiovascular outcomes compared to DP-EES. However, further long-term follow-up research is recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

Baremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS

Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...

متن کامل

Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.

BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...

متن کامل

Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis.

BACKGROUND The aim of this study was to compare the safety and efficacy of biodegradable-polymer (BP) drug-eluting stents (DES), bare metal stents (BMS), and durable-polymer DES in patients undergoing coronary revascularization, we performed a systematic review and network meta-analysis using a Bayesian framework. METHODS AND RESULTS Study stents included BMS, paclitaxel-eluting (PES), siroli...

متن کامل

Efficacy and Safety of Biodegradable Polymer Biolimus-Eluting Stents versus Durable Polymer Drug-Eluting Stents: A Meta-Analysis

BACKGROUNDS Drug-eluting stents (DES) with biodegradable polymers have been developed to address the risk of thrombosis associated with first-generation DES. We aimed to determine the efficacy and safety of biodegradable polymer biolimus-eluting stents (BES) versus durable polymer DES. METHODS Systematic database searches of MEDLINE (1950 to June 2013), EMBASE (1966 to June 2013), the Cochran...