Optical mapping of Langendorff-perfused rat hearts.
نویسندگان
چکیده
Optical mapping of the cardiac surface with voltage-sensitive fluorescent dyes has become an important tool to investigate electrical excitation in experimental models that range in scale from cell cultures to whole-organs([1, 2]). Using state-of-the-art optical imaging systems, generation and propagation of action potentials during normal cardiac rhythm or throughout initiation and maintenance of arrhythmias can be visualized almost instantly([1]). The latest commercially-available systems can provide information at exceedingly high spatiotemporal resolutions and were based on custom-built equipment initially developed to overcome the obstacles imposed by more conventional electrophysiological methods([1]). Advancements in high-resolution and high-speed complementary metal-oxide-semiconductor (CMOS) cameras and intensely-bright, light-emitting diodes (LEDs) as well as voltage-sensitive dyes, optics, and filters have begun to make electrical signal acquisition practical for cardiovascular cell biologists who are more accustomed to working with microscopes. Although the newest generation of CMOS cameras can acquire 10,000 frames per second on a 16,384 pixel array, depending on the type of sample preparation, long-established fluorescence acquisition technologies such as photodiode arrays, laser scanning systems, and cooled charged-coupled device (CCD) cameras still have some distinct advantages with respect to dynamic range, signal-to-noise ratio, and quantum efficiency([1, 3]). In the present study, Lewis rat hearts were perfused ex vivo with a crystalloid perfusate (Krebs-Henseleit solution) at 37 degrees C on a modified Langendorff apparatus. After a 20 minute stabilization period, the hearts were intermittently perfused with 11 mMol/L 2,3-butanedione monoxime to eliminate contraction-associated motion during image acquisition. For optical mapping, we loaded hearts with the fast-response potentiometric probe di-8-ANEPPS([4]) (5 microMol/L) and briefly illuminated the preparation with 475+/-15 nm excitation light. During a typical 2 second period of illumination, >605 nm light emitted from the cardiac preparation was imaged with a high-speed CMOS camera connected to a horizontal macroscope. For this demonstration, hearts were paced at 300 beats per minute with a coaxial electrode connected to an isolated electrical stimulation unit. Simultaneous bipolar electrographic recordings were acquired and analyzed along with the voltage signals using readily-available software. In this manner, action potentials on the surface of Langendorff-perfused rat hearts can be visualized and registered with electrographic signals.
منابع مشابه
Pharmaco-Electrophysiology of Isolated Perfused Rat Heart Assessed with Flexible Microelectrode Arrays
Background: Heart slices and enzymatically dissociated cardiomyocytes are used in cardiac safety pharmacology for extracellular recording using microelectrode array (MEA). The aim of this study was to set up and validate a vitro cardiac surface mapping system for studies pharmaco-electrophysiology effects in Langendorff perfused rat hearts by flexible MEA. Materials and Methods: Hearts isolated...
متن کاملLow-Cost Optical Mapping Systems for Panoramic Imaging of Complex Arrhythmias and Drug-Action in Translational Heart Models
Panoramic optical mapping is the primary method for imaging electrophysiological activity from the entire outer surface of Langendorff-perfused hearts. To date, it is the only method of simultaneously measuring multiple key electrophysiological parameters, such as transmembrane voltage and intracellular free calcium, at high spatial and temporal resolution. Despite the impact it has already had...
متن کاملOptical Mapping of Action Potentials and Calcium Transients in the Mouse Heart
The mouse heart is a popular model for cardiovascular studies due to the existence of low cost technology for genetic engineering in this species. Cardiovascular physiological phenotyping of the mouse heart can be easily done using fluorescence imaging employing various probes for transmembrane potential (V(m;)), calcium transients (CaT), and other parameters. Excitation-contraction coupling is...
متن کاملEffect of endotoxemia on heart rate dynamics in rat isolated perfused hearts
Introduction: Beat-to-beat variation in heart rate shows a complex dynamics, and this complexity is changed during systemic inflammatory response syndrome (e.g. sepsis). It is not known whether or not cardiac pacemaker dynamical rhythm is affected by sepsis. The aim of this study was to investigate heart rate dynamics of isolated heart as well as expression of pacemaker channels (HCN) in a r...
متن کاملHexokinase II and reperfusion injury: TAT-HK2 peptide impairs vascular function in Langendorff-perfused rat hearts.
RATIONALE Mitochondrial-bound hexokinase II (HK2) was recently proposed to play a crucial role in the normal functioning of the beating heart and to be necessary to maintain mitochondrial membrane potential. However, our own studies confirmed that mitochondria from ischemic rat hearts were HK2-depleted, yet showed no indication of depolarization and responded normally to ADP. OBJECTIVE To est...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of visualized experiments : JoVE
دوره 30 شماره
صفحات -
تاریخ انتشار 2009