Novel High Reliability Bandgap-based Under- Voltage-lockout Methods

نویسنده

  • HUI WANG
چکیده

In this paper, a novel method to build under-voltage-lockout (UVLO) circuit has been developed. The method based on bandgap reference voltage comparator, which take advantage of a reference voltage produced by itself realizes voltage compare, stability of parameters such as threshold point voltage, hysteretic range, without utilizing an extra bandgap reference voltage. An abstractive feature of the proposed circuit is that it achieves UVLO function by a simple structure, without complicated logic components. Therefore, its power consumption is low. With the presented method, the novel under voltage lock out circuit achieves hysteretic range of 2.39V; its turn-on voltage is 12.0V, and turn-off voltage is 9.61V at 25°C.Simulation results are based on 0.5 μm BCD process technologies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Proposed Under-voltage Lockout of Compensated Temperature Coefficient Threshold Voltage without Comparator

A proposed under-voltage lockout of compensated temperature coefficient threshold voltage without comparator is presented in this paper. The circuit achieves stability of threshold voltage without utilizing extra band gap reference voltage source and voltage comparator. In the temperature range of from -40°C to +125°C, variation of only 30mV of the threshold voltage occurs. The under-voltage lo...

متن کامل

Designing Auxiliary Power Supplies for High Efficiency and Low Standby Power

Auxiliary power supplies are required to have low standby power consumption at light-load conditions. These power supplies also require features such as low cost, high efficiency, and a Line Under-Voltage Lockout (UVLO) function to detect the input voltage so the main power supply does not operate at low input voltage ranges. Fairchild’s FSQ510 has been specifically designed for low standby pow...

متن کامل

Design and Control of a Novel hybrid Active Power Filter based on Load Harmonic Currents Separation with the aim of DC-link voltage minimization in voltage source converter

This paper proposes a new hybrid active power filter, including voltage source converter (VSC) based active power filter and Thyristor Controllable LC Passive Filter (TCLC-HAPF) for eliminating harmonic load current components and compensating reactive power. This new structure which is based on the separation of high and low-frequency components of load current idea can reduce the drawbacks of...

متن کامل

A High Precision Bandgap Reference Used in Power Management ICs

A 2.5V high precision BiCMOS bandgap reference with supply voltage range of 6V to 18V was proposed and realized. It could be applied to lots of Power Management ICs (Intergrated Circuits) due the high voltage. By introducing a preregulated current source, the PSRR (Power Supply Rejection Ratio) of 103dB at low frequency and the line regulation of 26.7μV/V was achieved under 15V supply voltage a...

متن کامل

Resistorless BJT bias and curvature compensation circuit at 3.4 nW for CMOS bandgap voltage references

A novel resistorless bipolar junction transistor (BJT) bias and curvature compensation circuit for ultra-low power CMOS bandgap voltage references (BGR) is introduced. It works in the nano-ampere current consumption range and under 1 V of power supply. The analytical behavior of the circuit is described, and simulation results for a 0.18 μm CMOS standard process are analysed. A junction voltage...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013