Achieving 'excellent' indoor air quality in commercial offices equipped with air-handling unit--respirable suspended particulate.
نویسندگان
چکیده
UNLABELLED A study was carried out to investigate the feasibility of achieving ultra low respirable suspended particulates (RSP) in commercial offices without major modification of existing ventilation systems by enhancing the particulates removal efficiency of existing central ventilation systems. Four types of filters which include pre-filters, cartridge filters, bag filters and high efficiency particulates air (HEPA) filters were tested in a commercial building in Causeway Bay. The results show that an RSP objective of <20 microg/m3 could be met by removing RSP from both the return air and outdoor air supply simultaneously. This level of performance is classed as 'excellent' by the Hong Kong Government, Environmental Protection Department. Filters with efficiency that exceed 80% placed both in the return air and outdoor air were sufficient to meet the objective. It is not necessary to install HEPA filters to achieve the 'excellent' class. The outdoor air filter has great influence on the steady state indoor RSP concentration while the effective cleaning rate is governed by the return air filter. Higher efficiency filters increased the static drop but the volume flow of the air fan was not affected significantly. The additional cost incurred was <5% of the existing operation cost. PRACTICAL IMPLICATIONS This paper reports a field study of RSP control for an indoor office environment. The results are directly applicable to building service engineering in the design of ventilation systems using air-handling units. Field observations indicated that indoor RSP in an office environment could be suppressed below 20 microg/m3 within 1 h by the simultaneous filtration of outdoor air and return air. Outdoor air filtration has a great influence on the steady state indoor concentration and return air filtration governs the cleaning rate. It is believed that the results of this study could be extended to the cleaning of other indoor pollutants such as volatile organic compounds.
منابع مشابه
Screening for Indoor Air Quality Express Assessment Protocol of Air-conditioned Offices
A successful Indoor Air Quality (IAQ) surveillance plan is essential for healthy and safe workplaces; yet it is costly to sample all air pollutants of the entire community. In Hong Kong, a voluntary IAQ certification scheme for workplaces proposes the acceptable concentration levels of nine common indoor air pollutants, namely carbon dioxide (CO2), carbon monoxide (CO), respirable suspended par...
متن کاملComparison of Respirable Particulate (PM4) Measturements from Direct- Reading Photometric Instruments and a Gravimentric Sampling Method
The National Environmental Management: Air Quality Act of 2004 states that people have the right to clean air and a healthy environment. Residents of low-income settlements are exposed to high concentrations of indoor air pollution due to the burning of solid fuels such as low-grade coal and wood for space heating and cooking. Long term exposure leads to degradation in the quality of life exper...
متن کاملEvaluation of Indoor Air Quality Screening Strategies: A Step-Wise Approach for IAQ Screening
Conducting a full indoor air quality (IAQ) assessment in air-conditioned offices requires large-scale material and manpower resources. However, an IAQ index can be adopted as a handy screening tool to identify any premises (with poor IAQ) that need more comprehensive IAQ assessments to prioritize IAQ improvements. This study proposes a step-wise IAQ screening protocol to facilitate its cost-eff...
متن کاملChemical Characterization of the Indoor Air Quality of a University Hospital: Penetration of Outdoor Air Pollutants
For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ). The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two outdoor locations and source samples were collected from a helicopter and an emergency power supply. V...
متن کاملAssessment of ambient air quality in urban centres of Haryana (India) in relation to different anthropogenic activities and health risks.
Considering the mounting evidences of the effects of air pollution on health, the present study was undertaken to assess the ambient air quality status in the fast growing urban centres of Haryana state, India. The samples were collected for total suspended particulate matter (TSPM), respirable suspended particulate matter (PM(10)), sulfur dioxide (SO(2)), and oxides of nitrogen (NO(2)) during ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Indoor air
دوره 16 2 شماره
صفحات -
تاریخ انتشار 2006