A free database of radionuclide voxel S values for the dosimetry of nonuniform activity distributions.
نویسندگان
چکیده
The increasing availability of SPECT/CT devices with advanced technology offers the opportunity for the accurate assessment of the radiation dose to the biological target volume during radionuclide therapy. Voxel dosimetry can be performed employing direct Monte Carlo radiation transport simulations, based on both morphological and functional images of the patient. On the other hand, for voxel dosimetry calculations the voxel S value method can be considered an easier approach than patient-specific Monte Carlo simulations, ensuring a good dosimetric accuracy at least for anatomic regions which are characterized by uniform density tissue. However, this approach has been limited because of the lack of tabulated S values for different voxel dimensions and radionuclides. The aim of this work is to provide a free dataset of values which can be used for voxel dosimetry in targeted radionuclide studies. Seven different radionuclides (89Sr, 90Y, 131I, 153Sm, 177Lu, 186Re, 188Re), and 13 different voxel sizes (2.21, 2.33, 2.4, 3, 3.59, 3.9, 4, 4.42, 4.8, 5, 6, 6.8 and 9.28 mm) are considered. Voxel S values are calculated performing simulations of monochromatic photon and electron sources in two different homogeneous tissues (soft tissue and bone) with DOSXYZnrc code, and weighting the contributions on the basis of the radionuclide emission spectra. The outcomes are validated by comparison with Monte Carlo simulations obtained with other codes (PENELOPE and MCNP4c) performing direct simulation of the radionuclide emission spectra. The differences among the different Monte Carlo codes are of the order of a few per cent when considering the source voxel and the bremsstrahlung tail, whereas the highest differences are observed at a distance close to the maximum continuous slowing down approximation range of electrons. These discrepancies would negligibly affect dosimetric assessments. The dataset of voxel S values can be freely downloaded from the website www.medphys.it.
منابع مشابه
Development of a free anthropomorphic voxel model of human body for wide-band computational electromagnetics dosimetry
To calculate and evaluate wave scattering and penetration of electromagnetic waves in different biological tissues it is necessary to use a realistic model of the human body, with all tissues resolved and separately assigned with appropriate electric/magnetic properties. We report the development of a realistic 3D whole-body human model that has been adapted for simulation in CST software, cont...
متن کاملMIRD Pamphlet No. 17: The Dosimetry of Nonuniform Activity Distributions—Radionuclide S Values at the Voxel Level
In collaboration with the MIRD Committee, Society of Nuclear Medicine: E.E. Watson (Chair), J.S. Robertson (Task Group Leader), W.E. Bolch, A.B. Brill, N.D. Charkes, D.R. Fisher, M.T. Hays, R.W. Howell, J.A. Siegel, S.R. Thomas and B.W. Wessels Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, Florida; Gaithersburg, Maryland; Department of Radiology, George...
متن کاملA CVH-based computational female pelvic phantom for radiation dosimetry simulation
Background: Accurate voxel phantom is needed for dosimetric simulation in radiation therapy for malignant tumors in female pelvic region. However, most of the existing voxel phantoms are constructed on the basis of Caucasian or non-Chinese population. Materials and Methods: A computational framework for constructing female pelvic voxel phantom for radiation dosimetry was performed base...
متن کاملDevelopment of Prototype Iranian male pelvic phantom for internal dosimetry
Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...
متن کاملPatient-specific dosimetry for 131I thyroid cancer therapy using 124I PET and 3-dimensional-internal dosimetry (3D-ID) software.
UNLABELLED Compared with conventional, whole-organ, S-factor-based dosimetry, 3-dimensional (3D), patient-specific dosimetry better accounts for radionuclide distribution and anatomic patient variability. Its accuracy, however, is limited by the quality of the cumulated activity information that is provided as input. This input has typically been obtained from SPECT and planar imaging studies. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 57 2 شماره
صفحات -
تاریخ انتشار 2012