Cone beam computed tomography data acquisition during VMAT delivery with subsequent respiratory phase sorting based on projection image cross-correlation.
نویسندگان
چکیده
Localization and verification of a tumor position was conventionally performed prior to radiotherapy. The present authors, in the past a few years, proposed in-treatment verification of the tumor position by simultaneously acquiring cone beam computed tomography (CBCT) data using an on-board kilovolt imaging system. Dose delivery was either rotational conformal 1) or volumetric modulated arc therapy (VMAT). 2,3) The resulting three-dimensional (3D) volume image was appropriate for still organs such as prostate. For respiratory moving cases such as lung tumors, image blurring may be observed thereby reducing the accuracy of the tumor localization. In the meantime, Sonke et al proposed four-dimensional (4D) CBCT for respiratory moving lung tumors 4) assuming that the motion of the diaphragm correlates well with that of a lung tumor. The respiratory phase was calculated from frame-by-frame changes of projection images after enhancing diaphragm-like features on the cranio-caudal axis. Another group also published similar results later. 5) Kavanagh et al proposed an alternative method for extracting a respiratory pattern from a set of projection images without relying on edge detection of the diaphragm position, where simple pixel value summation was employed followed by high pass filtering. 6) Just recently, in ESTRO annual meeting , Sonke presented 4D CBCT during VMAT delivery by extending their previous 4D CBCT research for a lung tumor. 7) In this letter, we present our preliminary clinical 4D CBCT imaging during VMAT delivery using Elekta Synergy (Crawly, UK). As was described in our previous report, 1) the current Synergy system does not allow simultaneous delivery of kV CBCT beams and MV rotational beams. Having known that kV portal imaging is available during MV rota-tional beam delivery, we developed in-house software for CBCT reconstruction by collecting all the kV portal images during gantry rotation. We have developed a new respiratory phase sorting algorithm based on image cross-correlation between adjacent two projection images. Image cross-correlation was previously used for registering a cone beam CT image with the planning CT image inside a specified region of interest while the former image was repeatedly shifted, and the patient treatment couch was displaced according to the shift vector for the highest correlation. 8) Similarly cross-correlation between the adjacent two projection images was calculated while one of the images was shifted stepwise, and the shift vector giving the highest correlation was considered as the tumor displacement caused by breathing. In this algorithm edge detection is not employed and …
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کامل4D digitally reconstructed radiography for verifying a lung tumor position during volumetric modulated arc therapy
We have proposed four dimensional (4D) digitally reconstructed radiography (DRR) for verifying a lung tumor position during volumetric modulated arc therapy (VMAT). An internal target volume (ITV) was defined based on two clinical target volumes (CTVs) delineated on maximum exhalation and maximum inhalation images acquired by 4D planning computed tomography (CT). A planning target volume (PTV) ...
متن کاملRespiratory correlated cone beam CT.
A cone beam computed tomography (CBCT) scanner integrated with a linear accelerator is a powerful tool for image guided radiotherapy. Respiratory motion, however, induces artifacts in CBCT, while the respiratory correlated procedures, developed to reduce motion artifacts in axial and helical CT are not suitable for such CBCT scanners. We have developed an alternative respiratory correlated proc...
متن کاملImpact of flattening-filter-free techniques on delivery time for lung stereotactic volumetric modulated arc therapy and image quality of concurrent kilovoltage cone-beam computed tomography: a preliminary phantom study
To the Editor, Volumetric modulated arc therapy (VMAT) serves as a means for stereotactic hypofractionated treatment of lung tumors [1]. The present authors proposed an efficient VMAT sequence by restricting leaf speeds of a multi-leaf collimator per gantry rotation angle to below 1 mm/degree, thereby reducing the dose delivery time down to 210 s for a D95 prescription dose of 50 Gy in four fra...
متن کامل4D registration and 4D verification of lung tumor position for stereotactic volumetric modulated arc therapy using respiratory-correlated cone-beam CT
We propose a clinical workflow of stereotactic volumetric modulated arc therapy (VMAT) for a lung tumor from planning to tumor position verification using 4D planning computed tomography (CT) and 4D cone-beam CT (CBCT). A 4D CT scanner, an Anzai belt and a BodyFix were employed to obtain 10-phase respiratory-correlated CT data for a lung patient under constrained breathing conditions. A plannin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of radiation research
دوره 52 1 شماره
صفحات -
تاریخ انتشار 2011