Correlation of blood pressure and the ratio of S1 to S2 as measured by esophageal stethoscope and wireless bluetooth transmission
نویسندگان
چکیده
UNLABELLED Objective : Esophageal stethoscope has the advantage of being non-invasive, easily placed and capability to monitor the heart sound. This study was designed to determine whether the ratio of S1 to S2 analyzed by esophageal stethoscope and wireless bluetooth transmission can be accurate indicator that express the correlation with blood pressure. METHODS Total 33 adult male and female without cardiac disorder and with normal heart rhythm were selected randomly as the subjects of this Study. Two microphones were used with one for acquisition of heart sound by connecting it to the esophageal stethoscope while the other was used to measure the background noise in the operating room. After having transmitted the heart sound measured with the esophageal stethoscope to the receiver by using bluetooth module, it was saved in PC and outputted, following removal of noise in the operating room and the respiratory sound. S1 and S2 were measured with computation of the ratio of S1 to S2. Correlations between the systolic blood pressure with each of the S1, S2 and ratio of S1 to S2 were examined by using correlation analysis. RESULTS The ratio of S1 to S2 displayed the highest correlation with the systolic blood pressure, with S1 and S2 also displaying positive correlation with the systolic blood pressure. CONCLUSION As the result of analysis of the heart sound and the systolic blood pressure measured by using the esophageal stethoscope, the radio of S1 to S2 displayed greater correlation with the systolic blood pressure in comparison to the S1.
منابع مشابه
A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia
Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...
متن کاملمقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی
Background and Purpose: Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope devic...
متن کاملThe correlation between the first heart sound and cardiac output as measured by using digital esophageal stethoscope under anaesthesia
OBJECTIVE The use of an esophageal stethoscope is a basic heart sounds monitoring procedure performed in patients under general anesthesia. As the size of the first heart sound can express the left ventricle function, its correlation with cardiac output should be investigated. The aim of this study was to investigate the effects of cardiac output (CO) on the first heart sound (S1) amplitude. Me...
متن کاملبررسی و مقایسه مقادیر فشار سیستولیک اندازه گیری شده بوسیله قسمت دیافراگم و بل گوشی در بیماران بستری در بیمارستان شهید بهشتی کاشان در سال 1372
This is a 9uasi experimental study to compare blood pressure measurements taken by both components of stethoscope, bell and diaphragm. Blood pressure was evaluated in fifty patients of fifteen years of age and older. Equal populations of both genders were selected randomly from infectious, surgery and internal medicine wards. Subjects with cardiac arrhythmia weren't included in the study. Fiv...
متن کاملNoise exposure and risk of hypertension: a cross-sectional study
Abstract Background: Previous studies have indicated an unspecific correlation between noise exposure and blood pressure disturbances. Blood pressure disturbances could be caused by the environmental hazards such as noise exposure. The aim of this study is to analyze whether there is a relationship between noise exposure and hypertension. Methods: Atotal sample of 218 workers workin...