Repeatability and Reproducibility Standard Deviations in the Measurement of Trace Moisture Generated Using Permeation Tubes

نویسندگان

  • Peter H. Huang
  • Raghu Kacker
چکیده

Permeation-tube moisture generators are used in industry as calibrated sources of water vapor and carrier gas mixtures. Measurements were made using three permeation-tube moisture generators of the type used in the semiconductor industry. This paper describes repeatability and reproducibility standard deviations in measurement of moisture concentration from such generators. Repeatability refers to measurements within a system and reproducibility refers to measurements between systems. Two independent methods were used to measure the realized concentration of water vapor. The first measurement, the calculated value, was determined using calibrated permeation rate of permeation-tube and flow rate of dry carrier gas. This is the industrial method of evaluating moisture concentration. The second measurement, the measured value, was determined using the low frost-point generator at the National Institute of Standards and Technology (NIST) and a quartz-crystal-micro-balance. Four pairs of independent measurements for each generator and for six nominal levels in the range from10 nL/L to 100 nL/L were made. The characteristic used to quantify repeatability and reproducibility standard deviations in industrial measurements is the calculated value minus the measured value. Repeatability standard deviation ranges from 1 nL/L to 2 nL/L, approximately. Reproducibility standard deviation ranges from 2 nL/L to 8 nL/L, approximately. The documentary ASTM standard E691-99 was used for both data validation and quantification of the repeatability and reproducibility standard deviations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

کاربرد روش استخراج فاز جامد و جاذب XAD-4 جهت تعیین مقدار کادمیوم در نمونه های مو و ناخن کارگران یک صنعت فلزی

Background and aims: Cadmium is a common industrial and environmental contaminant causing adverse health effects on respiratory system and kidney. This has been classified as a human carcinogen. Biological monitoring of cadmium and its measurement in urine, hair, and nail samples can be considered as an evaluation of the internal dose. Because of trace concentration of analytes in biological sa...

متن کامل

Trace Amounts Determination of Vanadium (V) Using a New Kinetic-Catalytic Reaction System

This study describes a new simple, sensitive and selective catalytic kinetic spectrophotometricmethod for the determination of vanadium (V). The method is based upon the catalytic effect ofvanadium (V) on the oxidation of Carminic acid by bromate in sulfuric acid media. The reaction wasfollowed spectrophotometrically by measuring the decrease in absorbance at 490 nm and thedependence of sensiti...

متن کامل

Electrochemical Behavior and Determination ‎of Phenylephrine at the Multi-Walled Carbon ‎Nanotubes/ionic Liquid Nanocomposite ‎Modified Electrode in the Presence of ‎Acetaminophen

A simple and high sensitive electrochemical method was developed for determination of phenylephrine (PHE) in the presence of acetaminophen (AC) at the carbon-ceramic electrode modified by multi-walled carbon nanotubes/ionic liquid nanocomposite (MWCNTs/IL/CCE). Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) and chronoamperometry methods were used for electrochemical studie...

متن کامل

Results of an interlaboratory method performance study for the size determination and quantification of silver nanoparticles in chicken meat by single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS)

Single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS) promises fast and selective determination of nanoparticle size and number concentrations. While several studies on practical applications have been published, data on formal, especially interlaboratory validation of sp-ICP-MS, is sparse. An international interlaboratory study was organized to determine repeatability and re...

متن کامل

Using thermogravimetry for weight loss monitoring of permeation tubes used for generation of trace concentration gas standards.

Permeation tubes are convenient analyte sources for generating standard gas mixtures (containing, in particular, volatile organic compounds) used in the calibration of analytical instruments. For small permeation rates, corresponding to trace levels of analytes, the calibration of permeation tubes is time-consuming. The use of thermogravimetry as a means to measure rapidly the weight loss at co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 108  شماره 

صفحات  -

تاریخ انتشار 2003