Evaluation of a new, semiquantitative screening culture device for urine specimens.

نویسندگان

  • J Ferguson
  • J Tanner
  • J M Miller
چکیده

The EZ Streak urine culture device (Difco Laboratories, Detroit, Mich.) combines the advantages of both the dip-slide and the classic urine culture technique, enabling bacterial enumeration and isolation following a simple inoculation step. Five hundred clean-catch urine specimens submitted by outpatients attending a health maintenance organization were used to compare the EZ Streak with culture using a 0.001-ml loop. Complete agreement of colony counts determined by the two methods was obtained for 114 (91.2%) of 125 positive specimens, but 99.2% of the results agreed in clinical interpretation, indicating the presence or absence of bacteriuria. Overall agreement between the EZ Streak and culture was 95.7%. The sensitivity and specificity of the EZ Streak were determined to be 98.4 and 99.4%, respectively. For this patient population, the EZ Streak was determined to be a reliable replacement for routine urine culture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis by AMPLICOR PCR of Chlamydia trachomatis infection in urine samples from women and men attending sexually transmitted disease clinics.

Screening of urine specimens from men for Chlamydia trachomatis infection by a commercial PCR assay (AMPLICOR C. trachomatis Test; Roche Diagnostic Systems, Inc., Branchburg, N.J.) is a sensitive and specific noninvasive diagnostic assay. Since screening of women for C. trachomatis infection with the AMPLICOR C. trachomatis Test has been limited to use with endocervical swab specimens, we condu...

متن کامل

Use of rapid screening tests in processing urine specimens by conventional culture and the AutoMicrobic system.

Two rapid urine screening tests, the Chemstrip LN (BioDynamics, Indianapolis, Ind.) and the Bac-T-Screen urine screening device (Marion Laboratories, Inc., Kansas City, Mo.), were evaluated as techniques to predict bacteriuria as quantitated by either conventional culture or the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). A total of 666 urine specimens were analyzed by both scree...

متن کامل

Evaluation of Clinitek 200 and Rapimat II/T for screening for urinary tract infection.

Two machines, the Clinitek 200 and the Rapimat II/T, were evaluated for their ability to screen urine samples for significant bacteriuria and other elements indicative of urinary tract pathology. The automated screening procedures were compared with a conventional approach of microscopy and quantitative culture for 1020 urine specimens obtained from patients in a 700 bed general hospital. When ...

متن کامل

Analysis of the disagreement between automated bioluminescence-based and culture methods for detecting significant bacteriuria, with proposals for standardizing evaluations of bacteriuria detection methods.

A fully automated method for detecting significant bacteriuria is described which uses firefly luciferin and luciferase to detect bacterial ATP in urine. The automated method was calibrated and evaluated, using 308 urine specimens, against two reference culture methods. We obtained a specificity of 0.79 and sensitivity of 0.75 using a quantitative pour plate reference test and a specificity of ...

متن کامل

Clinical evaluation of the Lumac bioluminescence method for screening urine specimens.

A bioluminescence method for screening urine cultures to provide rapid reporting of negative specimens and to select appropriate urine cultures for direct application of automated identification methods was evaluated. A total of 2,000 specimens were processed in the Lumac Biocounter (3M, St. Paul, Minn.), and the results were compared with quantitative culture techniques by using a 0.001-ml ino...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 33 5  شماره 

صفحات  -

تاریخ انتشار 1995