On-chip sample pretreatment using a porous polymer monolithic column for solid-phase microextraction and chemiluminescence determination of catechins in green tea.

نویسندگان

  • Ling Lin
  • Hui Chen
  • Huibin Wei
  • Feng Wang
  • Jin-Ming Lin
چکیده

A porous polymer monolithic column for solid-phase microextraction and chemiluminescence detection was integrated into a simple microfluidic chip for the extraction and determination of catechins in green tea. The porous polymer was prepared by poly(glycidyl methacrylate-co-ethylene dimethacrylate) and modified with ethylenediamine. Catechins can be concentrated in the porous polymer monolithic column and react with potassium permanganate to give chemiluminescence. The microfluidic chip is reusable with high sensitivity and very low reagent consumption. The on-line preconcentration and detection can be realized without an elution step. The enrichment factor was calculated to be about 20 for catechins. The relative chemiluminescence intensity increased linearly with concentration of catechin from 5.0 × 10(-9) to 1.0 × 10(-6) M and the limit of detection was 1.0 × 10(-9) M. The proposed method was applied to determine catechin in green tea. The recoveries are from 90% to 110% which benefits the actual application for green tea samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated in-tube solid phase microextraction coupled with HPLC-ES-MS for the determination of catechins and caffeine in tea.

A polypyrrole (PPY) coated capillary and several commercially available capillaries (capillary GC columns) were used to evaluate their extraction efficiencies for catechins and caffeine. Compared with commercial capillaries that were currently used for in-tube solid phase microextraction (SPME), the PPY coated capillary showed better extraction efficiency for all of the compounds studied. Elect...

متن کامل

Ordered Nanoporous Carbon Based Solid-Phase Microextraction for the Analysis of Nitroaromatic Compounds in Aqueous Samples

In this paper, the possibility of using a new ordered nanoporous carbon as a new fiber in headspace solid phase microextraction (HS-SPME) to determine of mononitrotoluenes (MNTs) in waste water is demonstrated. The structural order and textural properties of the ordered nanoporous carbon were studied by X Ray Diffraction (XRD), Scanning Electron Microscopy (SEM) images and nitrogen adsorpti...

متن کامل

Ion Pair Dispersive Liquid-Liquid Microextraction for the Determination of Trace Amounts of Copper(II) in Soil, Multivitamin Tablet, Tea and Water Samples Using Flame Atomic Absorption Spectrometry

Ion pair dispersive liquid- liquid microextraction (IP-DLLME) method combined with flame atomic absorption spectrometry was proposed for the determination of trace amounts of copper(II). By using pyrocatechol violet as chelating agent and cetyltrimethyl ammonium bromide as an ion pairing agent, the trace amount of copper(II) was extracted in chloroform. The factors influencing the formation cop...

متن کامل

Selective Extraction and Determination of Di(2-ethylhexyl) Phthalate in Aqueous Solution by HPLC Coupled with Molecularly Imprinted Solid-phase Extraction

Surface Molecularly Imprinted Polymer (SMIP) for selective adsorption of di(2-ethylhexyl) phthalate(DEHP) was prepared on the surface of silica gel which was modified by aminopropyltriethoxysilane and acryloyl chloride in a two-step method. The prepared SMIP was used to prepare Molecularly Imprinted Solid-Phase Extraction (MISPE) column for selective extraction of DEHP from aqueous solution...

متن کامل

Spectrophotometric determination of trace amount of malachite green from water with novel magnetic silica nanoparticles

A nano-hybrid based on polystyrene derivatives and magnetite was introduced as a new sorbent for pretreatment and determine the trace amount of malachite green from aqueous solution by spectrophotometry after preconcentration by solid phase extraction (SPE). UV–Vis spectrophotometer was used for determination of MG concentration after desorption of the dye by hydrochloric acid solution in the s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 136 20  شماره 

صفحات  -

تاریخ انتشار 2011