High Resolution X-Ray: A Reliable Approach for Quantifying Osteoporosis in a Rodent Model

نویسندگان

  • Omar Velasco
  • Aaron W. James
  • Greg Asatrian
  • Mark Ajalat
  • Tyler Pritchard
  • Siyouneh Novshadian
  • Anu Murthy
  • Georgina Bayani
  • Xinli Zhang
  • Kang Ting
  • Chia Soo
چکیده

Osteoporosis is the most common metabolic disease of bone, resulting in significant worldwide morbidity. Currently, there are insufficient imaging modalities available to evaluate osteoporotic bones in small animal models. Here, we demonstrate the feasibility of using high resolution X-ray imaging as a comparable measure of bone degeneration to dual-energy X-ray absorptiometry (DXA) in an osteoporosis rodent model. At week 0, animals underwent either an ovariectomy (OVX) or sham procedure (SHAM). DXA analysis was performed weekly to confirm and compare the bone degenerative changes induced by OVX. A comparison using high resolution X-ray imaging (Faxitron(®)) was then performed postmortem due to need of soft tissue removal. Two regions of interest (ROIs) were utilized: the distal third of the femur and the lumbar spine (L4/L5). It was observed that SHAM animals maintained a relatively constant bone mineral density (BMD), in comparison to OVX animals, whereby a significant decrease in BMD was appreciated. Post mortem X-ray scans were performed and converted to 8-bit color and quantified. A high level of agreement with DXA quantifications was observed with X-ray quantifications, and a significant correlation between the radiopacity, visualized by color distributions, and the DXA BMD values between animal groups was evident. Our study demonstrates the applicability of high resolution X-ray imaging both qualitatively and quantitatively as a reliable approach for quantifying osteoporosis in rodent osteoporotic models. With DXA being a highly user dependent modality, our technique is a unique secondary methodology to verify DXA findings and minimize inter-observer variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Qualitative Evaluation of Digital Hand X-rays is Not a Reliable Method to Assess Bone Mineral Density

Object: The gold standard for evaluating bone mineral density is dual energy x-ray absorptiometry (DEXA).  Prior studies have shown poor reliability using analog wrist X-rays in diagnosing osteoporosis. Our goal was to investigate if there was improved diagnostic value to visual assessment of digital hand X-rays in osteoporosis screening. We hypothesized that similar to analog counterparts, dig...

متن کامل

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner

Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...

متن کامل

Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis

Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...

متن کامل

Mandibular Trabecular Bone Analysis Using Local Binary Pattern for Osteoporosis Diagnosis

Background: Osteoporosis is a systemic skeletal disease characterized by low bone mineral density (BMD) and micro-architectural deterioration of bone tissue, leading to bone fragility and increased fracture risk. Since Panoramic image is a feasible and relatively routine imaging technique in dentistry; it could provide an opportunistic chance for screening osteoporosis. In this regard, numerous...

متن کامل