Evaluation of the ventilator-user interface of 2 new advanced compact transport ventilators.
نویسندگان
چکیده
BACKGROUND Mechanical ventilation during patient transport frequently utilizes compact portable pneumatic ventilators that have limited ventilator-settings options. New advanced transport ventilators should yield quality improvements, but their user-friendliness needs to be tested. OBJECTIVE To evaluate the ventilator-user interface of 2 new transport ventilators. METHODS This was a 2-center descriptive study in which the ventilator-user interfaces of the Oxylog 3000 and Elisée 250 were compared by 20 French senior emergency physicians who were initially unfamiliar with these ventilators. Each physician carried out 15 tasks with each ventilator and then assigned each ventilator a satisfaction score. RESULTS With the Elisée 250 the task success rate was significantly higher (85.6% vs 66.6% with the Oxylog 3000, p < 0.0001), and the total number of errors was lower (46 vs 113). The main errors were related to inspiratory flow settings with the Oxylog 3000 (31 errors), inspiratory-expiratory ratio settings with the Elisée 250 (11 errors), ventilation mode choice with the Oxylog 3000 (17 errors), trigger sensitivity setting with the Elisée 250 (16 errors) and the Oxylog 3000 (11 errors), and alarm range setting with the Oxylog 3000 (10 errors). The mean satisfaction score was significantly better with the Elisée 250 (81% +/- 7, range 64-92%) than with the Oxylog 3000 (66% +/- 10, range 49-87%) (p < 0.0001). CONCLUSIONS The Elisée 250 ventilator-user interface was easier to use than that of the Oxylog 3000. The applicability of these results to other types of users will require further studies, but the types of errors found in our study might help future users.
منابع مشابه
Evaluation of the user interface simplicity in the modern generation of mechanical ventilators.
OBJECTIVE We designed this study to evaluate the simplicity of the user interface in modern-generation mechanical ventilators. We hypothesized that different designs in the user interface could result in different rates of operational failures. SETTING A laboratory in a tertiary teaching hospital. DESIGN Crossover design. SUBJECTS Twenty-one medical resident physicians who did not possess...
متن کاملEvaluation of transport ventilators at mild simulated altitude: a bench study in a hypobaric chamber.
BACKGROUND Previous studies on ventilators used for air transport showed significant effects of altitude, in particular with regard to accuracy of the tidal volume (VT) and breathing frequency. The aim of the study was to evaluate transport ventilators under hypobaric conditions. METHODS We conducted a bench study of 6 transport ventilators in a Comex hypobaric chamber to simulate mild altitu...
متن کاملInter- and intra-hospital transport of the critically ill.
Intra- and inter-hospital transport is common due to the need for advanced diagnostics and procedures, and to provide access to specialized care. Risks are inherent during transport, so the anticipated benefits of transport must be weighed against the possible negative outcome during the transport. Adverse events are common in both in and out of hospital transports, the most common being equipm...
متن کاملPerformance comparison of 15 transport ventilators.
BACKGROUND Numerous mechanical ventilators are designed and marketed for use in patient transport. The complexity of these ventilators differs considerably, but very few data exist to compare their operational capabilities. METHODS Using bench and animal models, we studied 15 currently available transport ventilators with regard to their physical characteristics, gas consumption (duration of ...
متن کاملObjective evaluation of neonatal ventilators.
Choosing which ventilator to purchase can dramatically affect what type of care patients get, practitioners’ working environment, and the hospital’s “bottom line.” Choosing a ventilator is a complicated process, often confounded by competing stakeholders. Trying to balance the desires of the hospital management, physicians, and respiratory therapists can be tricky. Getting the right equipment f...