A study of micromachined displacement pumps for vacuum generation
نویسنده
چکیده
Micromachined vacuum pumps are one of the key components in miniature systems for chemical and biological analysis. Miniature sensors and analyzers are normally operated at the pressure range lower than a few millitorr. We are developing a micromachined vacuum pump that is comprised of a mechanical rough pump integrated with micromachined ion-pumps. The rough pump generates a low vacuum of tens of torr from atmospheric pressure for the ion-pumps to initialize. Field ionization and electron impact ionization pumps that connect to the rough pumps continue to pump from the low vacuum of tens of torr to high vacuum of millitorr or even microtorr. The focus of this thesis work is on the development of the micromachined rough pump. A micromachined displacement pump concept is adopted for the development of the chip scale vacuum rough pump. The micro displacement pump is designed with the aid of analytical and numerical modeling. The rough pump is fabricated by deep-reactive ion etching and other standard micromachining techniques. Systematic study into operation of this class of pumps allows us to now report on a pump that achieves 164 torr absolute pressure, which is to our knowledge the lowest measured pressure in a micromachined vacuum pump operated from atmospheric pressure. This performance improvement is significant in that it enables a base pressure of less than 35 torr for a two-stage design, which allows integration with the ion pump, thus leading to realization of miniature chemical and biological analyzers. More importantly, the understanding of the micromachined displacement pumps for vacuum generation has been greatly improved and a universal model has been developed, which is very powerful to describe and predict the micromachined displacement pump behavior for vacuum generation.
منابع مشابه
Micromachined Magnetic Actuators Using Electroplated Permalloy
Results on design, fabrication, and testing of silicon micromachined magnetic actuators are presented. Electroplated, low-stress permalloy (Ni80Fe20) material is the medium for magnetic interaction and force generation. The permalloy piece is supported by a structural plate, which consists of polycrystalline silicon thin film prepared by low-pressure chemical vapor deposition (LPCVD). Magnetic ...
متن کاملAN INTEGRATED SURFACE MICROMACHINED CAPACITIVE LATERAL ACCELEROMETER WITH 2μG/√Hz RESOLUTION
A capacitive position measurement interface minimizes noise from parasitics in the electromechanical interface and uses correlated double sampling to achieve better than 10Å/√Hz displacement resolution. This translates into 2μG/√Hz acceleration resolution when the device is operated in a vacuum.
متن کاملCHARACTERIZATION OF CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCERS IN AIR USING OPTICAL MEASUREMENTS Sean
Capacitive micromachined ultrasonic transducers (CMUTs) are efficient transmitters and receivers for air-coupled nondestructive evaluation applications [l]. In this paper, we present optical measurements on CMUTs with circular and rectangular membranes. Use of a laser interferometer permits accurate measurement of individual membrane displacements as well as characterization of mode shapes on t...
متن کاملDevelopment of Surface Micromachined Magnetic Actuators Using Electroplated Permalloy
Results on design, fabrication and testing of silicon micromachined magnetic actuators are presented. Magnetic actuators are capable of providing large force (on the order of mN) and large displacement (micrometer to millimeter range) within micro electromechanical devices and systems. Electroplated Permalloy (Ni80Fe20) material is the media for magnetic interaction and force generation. The Pe...
متن کاملWideband micromachined acoustic sensors with radio frequency detection
Silicon micromachining techniques permit batch fabrication of microphones that are small, reproducible, and inexpensive. However, many such sensors have limited bandwidth or are too fragile to be used in a humid, wet, or dusty outdoor environment. Microphones using capacitive micromachined ultrasonic transducer (CMUT) membranes and radio frequency (RF) detection overcome some of the problems as...
متن کامل