Six Standard Reference Materials (SRMs®) have been prepared by the National Institute of Standards and Technology (NIST) for the determination of PCBs as different Aroclor mixtures in methanol. Six additional SRMs of the same Aroclors in transformer oil have also been prepared. Specifically, solutions of Aroclors 1016, 1232, 1242, 1254, and 1260 have been gravimetrically prepared (individually) in methanol and transformer oil, mixed, and transferred to amber glass ampoules in approximately 1.2 mL aliquots. Gas chromatography with electron capture detection (GC-ECD) has been used to verify the gravimetric data for each solution and transformer oil SRM. Liquid chromatography was used for the isolation of the Aroclors from the transformer oil SRMs prior to GC-ECD analysis. Separate calibration solutions and oils were prepared with Aroclor levels similar to those in each methanol solution and transformer oil SRM and were processed alongside the samples. The GC-ECD response of each Aroclor was monitored relative to internal standards that were added to the complex mixtures for quantification. The gravimetric concentrations of Aroclors 1242 and 1254 in methanol were also examined by the same method of analysis (GC-ECD) using several different sources of Aroclors and two different capillary GC columns: a 5 % phenyl methylpolysiloxane phase and a relatively non-polar phase. The preparation of the materials, the gas chromatographic results, and the certified concentration values for each Aroclor SRM are described in this paper.
منابع مشابه
Characterization of a suite of ginkgo-containing standard reference materials.
A suite of three ginkgo-containing dietary supplement Standard Reference Materials (SRMs) has been issued by the National Institute of Standards and Technology (NIST) with certified values for flavonoid aglycones, ginkgolides, bilobalide, and selected toxic trace elements. The materials represent a range of matrices (i.e., plant, extract, and finished product) that provide different analytical ...
متن کاملValidation and application of an analytical method for determination of Persistent Organic Pollutants in Rainbow trout (Onchorhynchus mykiss) collected from Tehran retail markets
Persistent organic pollutants are a wide group of toxic and dangerous compounds. These organic compounds are chemically and physically stable even beams. In this study an analysis method for simultaneous determination of 18 persistent organic pollutants including eleven Organochlorine pesticides (OCPs): HCB, Dieldrin, Methoxychlor, α-, ϒ-Chlordane, α-, β-Endosulfan and o,p’-DDE, p,p’-DDE, o,p’-...
متن کاملDetermination of perfluorinated alkyl acid concentrations in human serum and milk standard reference materials.
Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated a...
متن کاملDevelopment of near infrared reflectance spectroscopy (NIRS) calibration model for estimation of oil content in a worldwide safflower germplasm collection
The development of NIRS calibration model as a rapid, precise, robust, and cost-effective method to estimate oil content in ground seeds of worldwide safflower germplasm collection grown under different agro-climatic conditions was the key objective of this research project. The oil content was measured by accelerated solvent extraction method in a total of 328 samples collected across 2004 (16...
متن کاملSimultaneous Determination of Hydrochlorothiazide and Enalapril Maleate in Pharmaceutical Formulations Using Fourier Transform Infrared Spectrometry
A new Fourier Transform-Infra Red (FT-IR) spectrometric method was developed for assaying hydrochlorothiazide (HCT) and enalapril maleate (ENM) in binary solid pharmaceutical formulations. Multivariate Partial Least Squares (PLS) method was used for calibration of derivative spectral data. Acetonitrile was used as solvent due to its spectral tran...
متن کامل