Treatment of axial data in three-dimensional PET.
نویسندگان
چکیده
Improved axial spatial resolution in positron emission tomography (PET) scanners will lead to reduced sensitivity unless the axial acceptance angle for the coincidences is kept constant. A large acceptance angle, however, violates assumptions made in most reconstruction algorithms, which reconstruct parallel independent slices, rather than a three-dimensional volume. Two methods of treating the axial information from a volume PET scanner are presented. Qualitative and quantitative errors introduced by the approximations are examined for simulated objects with sharp boundaries and for a more anatomically realistic distribution with smooth activity gradients.
منابع مشابه
One-Dimensional design of a three-stage axial compressor with Its 3D numerical simulation
The purpose of this study is to design a three-stage axial compressor with identical pressure ratio which makes an adequate pressure ratio and efficiency in design point conditions with rotational velocity of 38000rpm and mass flow rate of 3.2kg/s. First of all, considering some restrictions such as Dehaller number more than 0.7 in all sections of the stator and the rotor, and relative Mach num...
متن کاملThree-dimensional calculations of the magnetic fields in a finite superconducting hollow cylinder in an applied axial magnetic field
In this study, a set of self-consistent coupled-integral equations for the local magnetic flux and current distributions in a finite superconducting hollow cylinder under an axial magnetic field has been directly derived by using the Biot-Savart law within the framework of the critical-state model. The equations were first solved numerically in the three-dimensional space before obtaining the h...
متن کاملPerformance Modeling and Examination of Losses in the Axial -Flow Compressor and Comparisonwith Experimental Results
The performance prediction of axial flow compressors at different speeds and under various pressure ratio conditions are still being developed because of costly empirical experiments. One-dimensional modeling is a simple, fast and accurate method for performance prediction in any type of compressor with different geometries. In this approach, inlet flow conditions and compressor geometry are kn...
متن کاملImplementation of continuous 3D whole-body PET scanning using on-the-fly Fourier rebinning.
The continuous scanning mode in three-dimensional (3D) whole-body PET studies has the advantage of axial sensitivity uniformity over the majority of the axial FOV. However, this scan mode requires large data handling compared to conventional discrete scans. In this work, we have implemented and evaluated a new continuous 3D scan method using 'on-the-fly' Fourier rebinning. In this method, sinog...
متن کاملBackground-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study
Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 28 11 شماره
صفحات -
تاریخ انتشار 1987