Failure of the Percutaneous Intra - Aortic Balloon to Unwrap - A Case Report
نویسنده
چکیده
____________ _ An intra-aortic balloon which can be inserted percutaneously has become an attractive adjunct in the past few years. The major benefits of this technique are ease and speed of insertion and the lack of need for a surgical cutdown. Early concerns about post balloon removal hemorrhage due to the large catheter size ( 12 French) have largely proven to be unfounded. Early experience suggests that the most frequent problem associated with percutaneous insertion has been failure of the balloon to completely unwrap. This problem was observed in 17 of 96 patients (17 .8%) in whom the balloon was inserted perioperatively. Usually, the problem is recognized immediately. The balloon is then withdrawn, re-wrapped, and reinserted or replaced with another balloon. In two patients, failure to completely unwrap was not recognized until later. One patient had the balloon removed while another was simultaneously inserted into the contralateral femoral artery without complication followed by improved and normal balloon function. The second patient is presented depicting recognition of the problem and subsequent solution. Introduction ____________ _ The application of a catheter-mounted balloon placed in the descending aorta to provide counterReprint address: Steven E. Curtis, Box 3043, Duke University Medical Center, Durham, North Carolina 27710. Pr.esented at AmSECT's 20th International Conference, Hollywood, Flonda, April 26, 1982. pulsation was first described by Moulopoulos in 1962. 1 During the ensuing years, balloon configurations changed and were updated, based on previous experience and demand. The major changes were balloon design and smaller catheter size. This was due in large part to changes in indication for use such as acute myocardial infarction with resultant cardiogenic shock and prophylactic balloon insertion preoperatively3 in high risk patients. The early generation of balloons required a surgical cutdown for insertion and removal. In 1979, Bregman first described the use of an intra-aortic balloon which could be inserted percutaneously, using the technique of Seldinger. 5 The major benefits of the percutaneous insertion technique are simplicity and speed of insertion and the lack of need for surgical cutdown to insert and remove. As simplified as the technique of percutaneous insertion is, strict attention must be paid to details, assuring an acceptably low incidence of complications. 6 Meticulous attention must be directed to insertion so as to avoid vascular compromise or improper balloon position, and at removal, to avoid post-removal hemorrhage. An infrequent, but potential problem with the percutaneous balloon which has not previously been adequately described, is failure of the balloon to unwrap. This is encountered in those balloons which require manual wrapping and unwrapping. If the balloon fails to completely deploy following insertion, it is usually possible to identify that as the source of ineffective pumping in a matter of minutes. Incomplete unwrapping is characterized Volume 15, Number 1, 1983 The Journal of Extra-Corporeal Technology 9 by sub-optimal augmentation, alarms on the pumping console and contour of the balloon pressure tracing on the console. In two patients, it was not apparent until two to three hours after insertion that the balloons were not completely unwrapped. The following is a case report depicting delayed malfunction, secondary to improper unwrapping, in one of the two cases and its subsequent solution. Case Report ________________________ __ A 73 year-old female underwent re-operation for closure of a recurrent ventricular septal defect. Following the operation, the patient was in left ventricular failure, requiring increased inotropic support. Initial attempts to insert an intra-aortic balloon via the right femoral artery were without success. For the following twelve hours, the patient remained in a low output state and suffered a cardiac arrest. At this point, it was then possible to insert a percutaneous balloon via the left femoral artery. Only fair augmentation was achieved and chest x-ray showed the balloon to be positioned too high. Accordingly, the balloon was withdrawn two to three centimeters followed by an instant console indication of volume loss. At the same time, the pulse pressure in the femoral artery was noted to be narrowed. Balloon sounds which were previously present over the left chest were now absent. Attempts to identify a leak in the external balloon tubing, as well as a console problem, were without success. After sterile preparation and draping, the ligatures around the sheath were removed. The balloon was aspirated and easily withdrawn. A second balloon was then successfully inserted into the sheath, appropriately positioned, and functioned satisfactorily. Inspection of the withdrawn balloon indicated it was possible to withdraw it from the sheath as only the most proximal 30-35% of the balloon was unwrapped (Figure 1). Observations ________________________ ___ Initial observation of the balloon following removal discounted the possibility of balloon rupture during or after insertion. This was not considered initially as insertion was with ease and no obstruction was encountered. It was noticed, however, that the balloon was not completely unwrapped. With that observation, the question was why the delayed malfunction? In retrospect, the following appears the most likely explanation. The event triggering the alarm and exposing the problem was repositioning the balloon. This allowed a tract to develop to the balloon tip, allowing a second smaller segment to deploy (Figure 2). This was confirmed by placing the balloon in a basin of water and inflating to its 40 cc volume. Apparently, after initial insertion and incomplete unwrapping, the balloon console sensed the proximal 30-35% which unwrapped as the entire balloon. This allowed the system to function normally. As the balloon was withdrawn, a tract developed to the balloon tip and the console sensed this as a leak, alarmed, and appropriately ceased to operate. The proximal unwrapped segment was FIGURE 1. Balloon after removal showing only the most proximal 30-35% to be unwrapped. 10 The Journal of Extra-Corporeal Technology Volume 15, Number 1, 1983 FIGURE2. Initially, only area "A" was unwrapped. The tract then developed to the balloon tip "B". probably over-inflated and could not deflate in one cardiac cycle. This would manifest as an obstruction to distal flow and account for the narrow pulse pressure as observed in the femoral artery (Figure 3). The balloon was returned to the manufacturer where analysis revealed no structural defect. I>iscussion ______________________________ _ The intra-aortic balloon is the most frequently used form of mechanical support for circulatory instability. 7 Indications for its use and results are well documented. 8 •9 • Despite the benefits of using the balloon, there are complications associated with it use. 11 These complications are usually related to the vascular system. 12 • Initial reports 14 indicate a percutaneously inserted balloon may decrease vascular complications. The relative ease and speed of insertion of this balloon allow for
منابع مشابه
The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملIntestinal cholesterol embolism resulting from intra-aortic balloon pumping: a case report
INTRODUCTION Intra-aortic balloon pumping is used in elective percutaneous coronary intervention for increasing coronary blood flow. However, intra-aortic balloon pumping may decrease visceral blood flow and cause mesenteric ischemia by visceral artery obstruction. CASE PRESENTATION We report the case of a 79-year-old Asian man in whom elective percutaneous coronary intervention was performed...
متن کاملAbdominal aortic peripheral intervention to facilitate intra-aortic balloon pump support during high risk percutaneous coronary intervention: a case report
BACKGROUND The use of intra-aortic balloon pump (IABP) via the trans-femoral approach has been established for hemodynamic support in patients undergoing high-risk percutaneous coronary intervention (PCI). However, there are various challenges associated with its use, especially in patients with aortoiliac occlusive arterial disease. CASE PRESENTATION We describe a case of high-risk PCI with ...
متن کاملIABP deployment in critical care
The Intra Aortic Balloon Pump (IABP) is an established support in addition to pharmacologic treatment of the failing heart after myocardial infarction, unstable angina, cardiac surgery and percutaneous coronary intervention (PCI). The indication for IABP in acute myocardial infarction expanded to include support of severely ill patient during acute cardiac catheterization and myocardial revascu...
متن کاملThe Feasibility of Evidence- based Decision Making in a Toxicology Emergency Case
Evidence- Based Medicine (EBM) aims to bring the best available evidence into clinical practice. Different clinical methods of education such as in-patient rounds, follow up rounds, out-patients rounds, group sessions, grand rounds, lectures, and journal clubs could be held by EBM approach. The current text presents two interrelated case reports; a case report of EBM decision making in an emer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999