Small improvements in mechanical axis alignment achieved with MRI versus CT-based patient-specific instruments in TKA: a randomized clinical trial.
نویسندگان
چکیده
BACKGROUND Patient-specific instrumentation in TKA has the proposed benefits of improving coronal and sagittal alignment and rotation of the components. In contrast, the literature is inconsistent if the use of patient-specific instrumentation improves alignment in comparison to conventional instrumentation. Depending on the manufacturer, patient-specific instrumentation is based on either MRI or CT scans. However, it is unknown whether one patient-specific instrumentation approach is more accurate than the other and if there is a potential benefit in terms of reduction of duration of surgery. QUESTIONS/PURPOSES We compared the accuracy of MRI- and CT-based patient-specific instrumentation with conventional instrumentation and with each other in TKAs. The three approaches also were compared with respect to validated outcomes scores and duration of surgery. METHODS A randomized clinical trial was conducted in which 90 patients were enrolled and divided into three groups: CT-based, MRI-based patient-specific instrumentation, and conventional instrumentation. The groups were not different regarding age, male/female sex distribution, and BMI. In all groups, coronal and sagittal alignments were measured on postoperative standing long-leg and lateral radiographs. Component rotation was measured on CT scans. Clinical outcomes (Knee Society and WOMAC scores) were evaluated preoperatively and at a mean of 3 months postoperatively and the duration of surgery was analyzed for each patient. MRI- and CT-based patient-specific instrumentation groups were first compared with conventional instrumentation, the patient-specific instrumentation groups were compared with each other, and all three approaches were compared for clinical outcome measures and duration of surgery. RESULTS Compared with conventional instrumentation MRI- and CT-based patient-specific instrumentation showed higher accuracy regarding the coronal limb axis (MRI versus conventional, 1.0° [range, 0°-4°] versus 4.5° [range, 0°-8°], p < 0.001; CT versus conventional, 3.0° [range, 0°-5°] versus 4.5° [range, 0°-8°], p = 0.02), femoral rotation (MRI versus conventional, 1.0° [range, 0°-2°] versus 4.0° [range, 1°-7°], p < 0.001; CT versus conventional, 1.0° [range, 0°-2°] versus 4.0° [range, 1°-7°], p < 0.001), and tibial slope (MRI versus conventional, 1.0° [range, 0°-2°] versus 3.5° [range, 1°-7°], p < 0.001; CT versus conventional, 1.0° [range, 0°-2°] versus 3.5° [range, 1°-7°], p < 0.001), but the differences were small. Furthermore, MRI-based patient-specific instrumentation showed a smaller deviation in the postoperative coronal mechanical limb axis compared with CT-based patient-specific instrumentation (MRI versus CT, 1.0° [range, 0°-4°] versus 3.0° [range, 0°-5°], p = 0.03), while there was no difference in femoral rotation or tibial slope. Although there was a significant reduction of the duration of surgery in both patient-specific instrumentation groups in comparison to conventional instrumentation (MRI versus conventional, 58 minutes [range, 53-67 minutes] versus 76 minutes [range, 57-83 minutes], p < 0.001; CT versus conventional, 63 minutes [range, 59-69 minutes] versus 76 minutes [range, 57-83 minutes], p < .001), there were no differences in the postoperative Knee Society pain and function and WOMAC scores among the groups. CONCLUSIONS Although this study supports that patient-specific instrumentation increased accuracy compared with conventional instrumentation and that MRI-based patient-specific instrumentation is more accurate compared with CT-based patient-specific instrumentation regarding coronal mechanical limb axis, differences are only subtle and of questionable clinical relevance. Because there are no differences in the long-term clinical outcome or survivorship yet available, the widespread use of this technique cannot be recommended.
منابع مشابه
Restoration of the Mechanical Axis in Total Knee Artrhoplasty Using Patient-Matched Technology Cutting Blocks. A Retrospective Study of 132 Cases
Background: The aim of this study is to evaluate the accuracy of bone cuts and the resultant alignment, using theMyKnee patient specific cutting blocks.Methods: We retrospectively reviewed 132 patients undergoing primary TKR for osteoarthritis by one single surgeon.The operative time, the preoperative Hip-Knee-Ankle (HKA) axis based on the CT-scan, the postoperative HKA axisbased on long axis s...
متن کاملComparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کاملThe Chitranjan S. Ranawat Award : No Difference in 2-year Functional Outcomes Using Kinematic versus Mechanical Alignment in TKA: A Randomized Controlled Clinical Trial.
BACKGROUND Neutral mechanical alignment (MA) in total knee arthroplasty (TKA) aims to position femoral and tibial components perpendicular to the mechanical axis of the limb. In contrast, kinematic alignment (KA) attempts to match implant position to the prearthritic anatomy of the individual patient with the aim of improving functional outcome. However, comparative data between the two techniq...
متن کاملComponent alignment during total knee arthroplasty with use of standard or custom instrumentation: a randomized clinical trial using computed tomography for postoperative alignment measurement.
BACKGROUND Patient-specific femoral and tibial cutting blocks produced with use of data from preoperative computed tomography (CT) or magnetic resonance imaging (MRI) scans have been employed recently to optimize component alignment in total knee arthroplasty. We report the results of a randomized controlled trial in which CT scans were used to compare postoperative component alignment between ...
متن کاملComponent position alignment with patient-specific jigs in total knee arthroplasty.
BACKGROUND The failure to restore mechanical alignment and appropriate rotational axis intraoperatively has been described as one of the most common causes of implant failure in total knee arthroplasty (TKA). Both conventional and computer-assisted TKA have their limitations. Patient-specific jigs (PSJ) offer a possible alternative method for TKA. The aim of this study was to investigate if the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 472 10 شماره
صفحات -
تاریخ انتشار 2014