Comparison of lateral thermal spread using monopolar and bipolar diathermy, and the bipolar vessel sealing system ThermoStapler™ during thyroidectomy.

نویسندگان

  • Jan Brzeziński
  • Karolina Kałużna-Markowska
  • Maciej Naze
  • Grzegorz Stróżyk
  • Marek Dedecjus
چکیده

UNLABELLED Electric devices enabling the maintenance of haemostasis during surgery have found application in modern thyroidectomy procedures. The haemostatic effect is associated with generation of heat, which apart from the intended result may bring about thermal tissue injury. The aim of the study was to determine the thermal spread around the active tip of electric devices in the operating field during total thyroidectomy, and the safe temperature range during the operation of studied devices. MATERIALS AND METHODS Over 14 months from December 2009 until January 2011, 76 total thyroidectomy procedures were analysed. The surgeries employed mono- and bipolar diathermy as well as the ThermoStapler™ bipolar vessel sealing system. During the procedures, the thermal spread around the active tips of used electric devices was recorded with the use of high-definition camera. Comparable 5-second periods of electric device use at two power ranges (30 W and 50 W) were selected from the recorded material. The highest temperature of the active tip of electric devices was determined, and the 42°C isotherm was found with the use of computer image analysis, thus determining the safe distance of important anatomic structures from the active tip of the electric device. RESULTS The temperature spread around the active tips of electric devices was recorded and the 42°C isotherm was determined. The diameter of this isotherm at the end of operation differed statistically significantly depending on the type of electric devices and power settings. The highest temperature, at both power ranges, was recorded for the bipolar vessel sealing system, while the lowest - for bipolar diathermy; at the same time a significantly lower 42°C isotherm diameter was found for ThermoStapler™ as compared with other devices. In all studied cases, the largest heat spread was found for monopolar diathermy. CONCLUSIONS The mean safe distance of the active tip of an electric device from important anatomic structures is 5 mm and depends on the device type and its power settings. Monopolar diathermy causes the strongest heating of surrounding tissues, and the ThermoStapler™ bipolar vessel sealing system, despite producing the highest temperature during operation, causes relatively small thermal injury to the surrounding tissues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

COmPARISON Of LAtERAL thERmAL SPREAd uSING mONOPOLAR ANd bIPOLAR dIAthERmy, ANd thE bIPOLAR vESSEL SEALING SyStEm thERmOStAPLERtm duRING thyROIdECtOmy*

Electric devices enabling the maintenance of haemostasis during surgery have found application in modern thyroidectomy procedures. The haemostatic effect is associated with generation of heat, which apart from the intended result may bring about thermal tissue injury. the aim of the study was to determine the thermal spread around the active tip of electric devices in the operating field during...

متن کامل

Dissection of mesoappendix in laparoscopic appendectomy: a comparison of monopolar cautery and bipolar vessel sealing system

Aim: Various technique and different instruments like endoscopic stapler, endoscopic clip, monopolar cautery, harmonic scalpel, and bipolar vessel sealer can be used in the dissection of appendix mesentery when performing laparoscopic appendectomy. The aim of this study is to evaluate the effects of using monopolar cautery and bipolar vascular sealing instruments in the dissection of mesentery ...

متن کامل

In silico evaluation of geometry variations with respect to the thermal spread during coagulation of egg white using bipolar vessel sealing instruments

BACKGROUND Bipolar vessel sealing is an efficient electrosurgical procedure for the occlusion of blood vessels particularly during minimally invasive surgery. Reliable knowledge of the thermal spread is crucial for a safe application of bipolar vessel sealing instruments when operating close to thermo-sensitive structures, such as nerves. The evolution of the thermal spread over time and space ...

متن کامل

Comparison of Mono and Bipolar Electrocoagulation in Laparoscopic Ovariohysterectomy in Dogs

Objective- To evaluate the clinical safety and superiority of monopolar and bipolar electrocauter in laparoscopic ovariohysterectomy in dogs. Design-Elective experimental study Animals- Twenty four mixed breed healthy adult female dogs. Procedures-The dogs divided into two equal groups. Laparoscopic ovariohysterectomy performed using either monopolar (n=12) or bipolar (n=12) electrocoagulati...

متن کامل

Validation of a Laparoscopic Ferromagnetic Technology-based Vessel Sealing Device and Comparative Study to Ultrasonic and Bipolar Laparoscopic Devices

INTRODUCTION Ferromagnetic heating is a new electrosurgery energy modality that has proven effective in hemostatic tissue dissection as well as sealing and dividing blood vessels and vascularized tissue. The purpose of this study was to evaluate a ferromagnetic-based laparoscopic vessel sealing device with respect to sealing and dividing vessels and vascularized tissue and to compare performanc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Polski przeglad chirurgiczny

دوره 83 7  شماره 

صفحات  -

تاریخ انتشار 2011