A validated spectrofluorimetric method for the determination of nifuroxazide through coumarin formation using experimental design
نویسندگان
چکیده
BACKGROUND Nifuroxazide (NF) is an oral nitrofuran antibiotic, having a wide range of bactericidal activity against gram positive and gram negative enteropathogenic organisms. It is formulated either in single form, as intestinal antiseptic or in combination with drotaverine (DV) for the treatment of gastroenteritis accompanied with gastrointestinal spasm. Spectrofluorimetry is a convenient and sensitive technique for pharmaceutical quality control. The new proposed spectrofluorimetric method allows its determination either in single form or in binary mixture with DV. Furthermore, experimental conditions were optimized using the new approach: Experimental design, which has many advantages over the old one, one variable at a time (OVAT approach). RESULTS A novel and sensitive spectrofluorimetric method was designed and validated for the determination of NF in pharmaceutical formulation. The method was based upon the formation of a highly fluorescent coumarin compound by the reaction between NF and ethylacetoacetate (EAA) using sulfuric acid as catalyst. The fluorescence was measured at 390 nm upon excitation at 340 nm. Experimental design was used to optimize experimental conditions. Volumes of EAA and sulfuric acid, temperature and heating time were considered the critical factors to be studied in order to establish an optimum fluorescence. Each two factors were co-tried at three levels. Regression analysis revealed good correlation between fluorescence intensity and concentration over the range 20-400 ng ml-1. The suggested method was successfully applied for the determination of NF in pure and capsule forms. The procedure was validated in terms of linearity, accuracy, precision, limit of detection and limit of quantification. The selectivity of the method was investigated by analysis of NF in presence of the co-mixed drug DV where no interference was observed. The reaction pathway was suggested and the structure of the fluorescent product was proposed. Statistical comparison between the presented method and a reported spectrophotometric one was carried out on pure and pharmaceutical formulation and revealed no significant difference. CONCLUSION The proposed method was considered economic, accurate, precise and highly sensitive. It could be easily applied in laboratory quality control for the analysis of NF in pure form and in pharmaceutical dosage form.
منابع مشابه
Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کاملDevelopment of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کاملSolid Phase Extraction Using Modified Magnetic Iron Oxide Nanoparticles for Extraction and Spectrofluorimetric Determination of Carvedilol in Human Plasma Samples
A new analytical approach was developed involving magnetic solid–phase extraction and spectrofluorimetric determination of carvedilol in human plasma samples. A plasma sample was prepared and adjusted to pH 8.2–10, then carvedilol was quickly extracted using iron oxide magnetic nanoparticles modified by the surfactant cetyltrimethylammonium bromide and determined to apply spectrofluorimetry...
متن کاملA Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design
this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...
متن کاملA Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design
this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...
متن کامل