Attenuation Correction of Pet Image Reconstructed Based on Direct Filtering of the Raw Data Acquired Using Mcnpx Code
نویسندگان
چکیده
This paper presents the Monte Carlo simulation of the Positron Emission Tomography (PET) scanning technique using MCNPX code. The raw data generated by general MCNPX code contain a lot of unnecessary information for the image reconstruction process. This requires a large memory to store all this information. In order to reduce the needed memory, we introduce some modifications on the MCNPX code source in order to be able to write directly the important data representing the coincidence events detected by the detector pairs along the lines of response (LORs). These data are acquired as a result of launching two simulations on a uniform cylindrical positron emitter source in water-filled environment. Thereafter, from the object’s geometry, knowledge of the materials in this object and the acquired simulation data, the attenuation correction map has been calculated and applied to the acquired data during PET image reconstruction process.
منابع مشابه
New approach for attenuation correction in SPECT images, using linear optimization
Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...
متن کاملA novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study
In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...
متن کاملComparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data
Introduction: The advent of dual-modality PET/CT scanners has revolutionized clinical oncology by improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates a noise-free attenuation map (6map). CTAC methods include scaling, s...
متن کاملEstimation of fetal absorbed dose from low-dose attenuation-correction CT in PET / CT imaging by using the Body Builder Phantom
One of the methods of studying the physiology and metabolism of important tissues such as the heart, brain and cancer tumors is the use of PET/CT System. A small number of patients are pregnant women who undergo a PET/CT scan due to lack of knowledge about pregnancy or due to dire clinical need. The final dose received by the fetus is based on three factors: the absorbed dose of the fetal tissu...
متن کاملEvaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...