Application of pulsed UV-irradiation and pre-coagulation to control ultrafiltration membrane fouling in the treatment of micro-polluted surface water.

نویسندگان

  • Wenzheng Yu
  • Luiza C Campos
  • Nigel Graham
چکیده

A major cause of ultrafiltration (UF) membrane fouling is the accumulation of microorganisms and their associated soluble products. To mitigate fouling the application of pulsed short-wavelength ultraviolet (UVC) light (around 254 nm) within the membrane tank together with pre-coagulation was investigated. In mini-pilot-scale tests carried out in parallel with conventional pre-treatment (CUF), the impact of pulsed UV (CUF-UV) at different UV irradiances and fluxes on the increase of trans-membrane pressure (TMP) was evaluated and explained in terms of the quantity and nature of membrane deposits in the membrane cake layer and pores. The results indicated that at a flux of 20 L m-2 h-1, the pulsed UV (1 min within 31 min cycle) at 3.17 × 10-2 W/cm2 prevented any measureable increase in TMP over a period of 32 days, while there was a fourfold increase in TMP for the conventional pre-treatment. For the CUF-UV system the concentration of bacteria and soluble microbial products was much less than the conventional CUF system, and the cake layer was thinner and contained less biopolymers (proteins and polysaccharides). In addition, the pores of the CUF-UV membrane appeared to have less organic deposits, and particularly fractions with a high molecular weight (>10 kDa). At a lower UV irradiance (1.08 × 10-2 W/cm2), or higher flux (40 L m-2 h-1) with the same UV irradiance, there was a measurable increase in TMP, indicating some fouling of the CUF-UV membrane, but the rate of TMP development was significantly lower (∼50%) than the conventional CUF membrane system. Overall, the results show the potential advantages of applying intermittent (pulsed) UVC irradiation with coagulation to control UF membrane fouling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pretreatment and Membrane Hydrophilic Modification to Reduce Membrane Fouling

The application of low pressure membranes (microfiltration/ultrafiltration) has undergone accelerated development for drinking water production. However, the major obstacle encountered in its popularization is membrane fouling caused by natural organic matter (NOM). This paper firstly summarizes the two factors causing the organic membrane fouling, including molecular weight (MW) and hydrophili...

متن کامل

Prevention of PVDF ultrafiltration membrane fouling by coating MnO2 nanoparticles with ozonation

Pre-treatment is normally required to reduce or control the fouling of ultrafiltration (UF) membranes in drinking water treatment process. Current pre-treatment methods, such as coagulation, are only partially effective to prevent long-term fouling. Since biological activities are a major contributor to accumulated fouling, the application of an oxidation/disinfection step can be an effective c...

متن کامل

Fabrication of Nanofiltration Membrane from Polysulfone Ultrafiltration Membrane Via Photo olymerization

UV-induced grafting technique was used as a flexible method for surface modification of Polysulfone (PSf) ultrafiltration (UF) membranes in order to prepare hydrophilic nanofiltration (NF) membranes. Flat sheet Polysulfone (PSf) ultrafiltration membranes were prepared via phase inversion method. N-methylene-2-pyrrolidone (NMP) and polyethylene glycol (PEG) of three different molecular weights (...

متن کامل

Preparation and Characterization of CA−PEG−TiO2 Membranes: Effect of PEG and TiO2 on Morphology, Flux and Fouling Performance

Modified cellulose acetate (CA) membranes were prepared by dissolving the polymers in a mixture of acetone (AC) and N, N dimethylacetamide (DMAc) (70:30) solvent and deionized (DI) water was used in the coagulation bath. The introduction of polyethylene glycol (PEG) additive and TiO2 nanoparticles (NPs) into the casting solution has changed the structures of the resulting membranes during the p...

متن کامل

Fouling and Rejection Characteristic of Humic Substances in Polysulfone Ultrafiltration Membrane

In this study, the ultrafiltration membrane for humic substance removal was prepared by blending polysulfone with a high concentration of PEG400 as additives. The influences of the additive to the fouling resistance capability and humic substances rejection of the polysulfone membrane were investigated. The addition of 35%wt of PEG400 concentration improved the pure water flux up to 200, but re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Water research

دوره 107  شماره 

صفحات  -

تاریخ انتشار 2016