Abstract. Pulsed photoacoustic measurements have been carried out in toluene at 532 nm wavelength using a Q-switched frequency doubled Nd:YAG laser. The variation of photoacoustic signal amplitude with incident laser power indicates that at lower laser powers one photon absorption takes place at this wavelength while a clear two photon absorption occurs in this liquid at higher laser powers. The studies made here demonstrate that pulsed photoacoustic technique is simple and effective for the investigation of multiphoton processes in liquids.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Pulsed Photoacoustic Technique for the Study of Nonlinear Processes in Liquids

Pulsed photoacoustic measurements have been carried out in toluene, benzene and carbon disulphide liquids using 532 nm radiation from a Q-switched frequency doubled Nd:YAG laser. The present chapter deals with the detection and analysis of the photoacoustic effect in certain organic liquids in the visible region. The variation of photoacoustic signal am­ plitude with incident laser power indica...

متن کامل

Photoacoustic signal saturation and optical limiting in C70-toluene solution

Riju C. Issac S. S. Harilal Geetha K. Varier C. V. Bindhu V. P. N. Nampoori C. P. G. Vallabhan Cochin University of Science and Technology International School of Photonics Laser Division Cochin 682 022, India Abstract. Pulsed photoacoustic studies in solutions of C70 in toluene are made using the 532-nm radiation from a frequency-doubled Nd:YAG laser. It is found that contrary to expectation, ...

متن کامل

Light Dependent Resistance as a Sensor in Spectroscopy Setups Using Pulsed Light and Compared with Electret Microphones

Light-dependent resistances (LDR) are cheap light sensors. A less known light detector is the electret microphone, whose electret membrane functions as a perfect absorber, but only detects pulsed light. The aim of this study was to analyze the use of a LDR and an electret microphone as a light sensor in an optical spectroscopy system using pulsed light. A photoacoustic spectroscopy setup was us...

متن کامل

The advantage of using a diode laser instead of a Q-switched laser in photoacoustic imaging of tissues

Photoacoustic (PA) imaging of biological tissues using laser diodes instead of conventional Q switched pulsed systems provides an attractive alternative for biomedical applications. However, the relatively low energy of laser diodes operating in the pulsed regime, results in generation of very weak acoustic waves, and low signal-to-noise ratio (SNR) of the detected signals. This problem can be ...

متن کامل

Integrated hollow-core fibers for nonlinear optofluidic applications.

A method to fabricate all-in-fiber liquid microcells has been demonstrated which allows for the incorporation of complex hollow-core photonic crystal fibers (HCPCFs). The approach is based on a mechanical splicing method in which the hollow-core fibers are pigtailed with telecoms fibers to yield devices that have low insertion losses, are highly compact, and do not suffer from evaporation of th...