Mass preserving image registration for lung CT

نویسندگان

  • Vladlena Gorbunova
  • Jon Sporring
  • Pechin Lo
  • Martine Loeve
  • Harm A. Tiddens
  • Mads Nielsen
  • Asger Dirksen
  • Marleen de Bruijne
چکیده

This paper presents a mass preserving image registration algorithm for lung CT images. To account for the local change in lung tissue intensity during the breathing cycle, a tissue appearance model based on the principle of preservation of total lung mass is proposed. This model is incorporated into a standard image registration framework with a composition of a global affine and several free-form B-Spline transformations with increasing grid resolution. The proposed mass preserving registration method is compared to registration using the sum of squared intensity differences as a similarity function on four groups of data: 44 pairs of longitudinal inspiratory chest CT scans with small difference in lung volume; 44 pairs of longitudinal inspiratory chest CT scans with large difference in lung volume; 16 pairs of expiratory and inspiratory CT scans; and 5 pairs of images extracted at end exhale and end inhale phases of 4D-CT images. Registration errors, measured as the average distance between vessel tree centerlines in the matched images, are significantly lower for the proposed mass preserving image registration method in the second, third and fourth group, while there is no statistically significant difference between the two methods in the first group. Target registration error, assessed via a set of manually annotated landmarks in the last group, was significantly smaller for the proposed registration method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Weight Preserving Image Registration for Monitoring Disease Progression in Lung CT

We present a new image registration based method for monitoring regional disease progression in longitudinal image studies of lung disease. A free-form image registration technique is used to match a baseline 3D CT lung scan onto a following scan. Areas with lower intensity in the following scan compared with intensities in the deformed baseline image indicate local loss of lung tissue that is ...

متن کامل

Registration - based Assessment of Regional Lung Function via Volumetric CT Images of 1 Normals vs . Severe Asthmatics

22 The purpose of this work is to explore the use of image registration-derived variables associated 23 with computed tomographic (CT) imaging of the lung acquired at multiple volumes. As an 24 evaluation of the utility of such an imaging approach, we explore two groups at the extremes of 25 population ranging from normals to severe asthmatics. A mass preserving image registration 26 technique ...

متن کامل

Compressible image registration for thoracic computed tomography images

We developed a method for the calculation of dynamic ventilation images from four dimensional computed tomography (4D CT) images. A voxel mapping produced by applying deformable image registration to the components of the 4D CT image data set is central to the calculation. Current algorithms, such as optical flow, assume incompressibility in their formulation which is inaccurate for lung tissue...

متن کامل

Registration-based assessment of regional lung function via volumetric CT images of normal subjects vs. severe asthmatics.

The purpose of this work was to explore the use of image registration-derived variables associated with computed tomographic (CT) imaging of the lung acquired at multiple volumes. As an evaluation of the utility of such an imaging approach, we explored two groups at the extremes of population ranging from normal subjects to severe asthmatics. A mass-preserving image registration technique was e...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image analysis

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2012