Factors affecting the location and shape of face seal leak sites on half-mask respirators.

نویسندگان

  • Riedar Kent Oestenstad
  • Alfred A Bartolucci
چکیده

While there have been a number of studies on the effect of leak site and shape on the magnitude of measured leakage through respirator face seals, there have been very few studies to identify the location and size of these leaks. In a previous study we used a method of identifying the location and shape of respirator leaks on a half-mask respirator by the deposition of a fluorescent tracer during a fit test, and testing for their association with facial dimensions. The purpose of this study was to apply that methodology to conduct multiple fit tests to determine if gender, respirator brand, repeated fit tests, and test exercises affected the location and shape of face seal leak sites. Categorical analysis found that none of these factors had a significant effect on the location and shape of leaks. General linear model analysis found some significant effects of the study factors on leaks, but facial dimensions had a greater effect, and there were significant differences between facial dimensions of subjects with a leak and those without. Significant differences in leak site distributions between this and the previous study may have been due to differences in facial dimensions and racial/ethnic composition. Twice as many diffuse leaks as point leaks were observed in both studies, indicating that slit-like leaks would be most appropriate on mannequins used in laboratory respirator leakage studies, and in respirator flow and penetration models. That the study factors had no significant effects in the categorical analysis, significant effects for facial dimensions were found in the linear analysis, and leak site distribution differences between this and our previous study may have been affected by differences in facial dimensions, indicate that, in addition to size, the shape of an individual's face may be an important determinant of leak sites on a half-mask respirator. This would have implications for the design of respirator facepieces and in the selection of respirators for individual wearers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of half-face respirator fit in an Iranian petrochemical company's workers

Introduction: The performance of respirator-face piece is depending on a good contact between the worker's face and the respirator. Improper sealing can cause reduction in performance of respirators to protect health and safety of workers against risks related to chemical agents at work. This study is aimed to evaluate the fitness of half-face respirators and other related factors on it in an...

متن کامل

Evaluation of Full-Facepiece Respirator Fit on Fire Fighters in the Municipality of Jeddah, Saudi Arabia

The purpose of this study was to assess the effect of personal variables on the fit of the respirators used by firefighters and workers in highly polluted environments. However, resistance from many plants managers was met to conduct the study on their workers. Therefore, we were forced to limit the study on firefighters who were found very cooperative. Forty volunteer firefighters from differe...

متن کامل

Laboratory evaluation of the particle size effect on the performance of an elastomeric half-mask respirator against ultrafine combustion particles.

OBJECTIVES This study quantified the particle size effect on the performance of elastomeric half-mask respirators, which are widely used by firefighters and first responders exposed to combustion aerosols. METHODS One type of elastomeric half-mask respirator equipped with two P-100 filters was donned on a breathing manikin while challenged with three combustion aerosols (originated by burning...

متن کامل

Particle Size-Selective Assessment of Protection of European Standard FFP Respirators and Surgical Masks against Particles-Tested with Human Subjects

This study was conducted to investigate the protection of disposable filtering half-facepiece respirators of different grades against particles between 0.093 and 1.61  μm. A personal sampling system was used to particle size-selectively assess the protection of respirators. The results show that about 10.9% of FFP2 respirators and 28.2% of FFP3 respirators demonstrate assigned protection factor...

متن کامل

Effects of Wearing N95 Respirators and Surgical Masks during Progressive Running Exercise and High-Intensity Interval Training on Time- and Frequency-Domain Indicators of Heart Rate Variability

Background and purpose: Wearing face masks has become popular during the COVID-19 pandemic as a measure to prevent the spread of the virus. Some studies have pointed out the intervening role of these masks in the effect of exercise on the cardiovascular system. This study aimed at examining and comparing the effects of masking (N95 respirators and surgical masks) and not wearing a mask during e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of occupational and environmental hygiene

دوره 7 6  شماره 

صفحات  -

تاریخ انتشار 2010