Role of echocardiography and phonocardiography in diagnosis of mitral paraprosthetic regurgitation with Starr-Edwards prostheses.

نویسندگان

  • H C Miller
  • D G Gibson
  • J D Stephens
چکیده

Twenty-three patients who were symptomatic after mitral valve replacement, and in whom mitral paraprosthetic regurgitation was a possible cause of deterioration, were investigated by cardiac catheterization, phonocardiography, and echocardiography. Severe paraprosthetic regurgitation was present in ii patients and slight regurgitation in 2 patients. Two patients had aortic regurgitation which was responsible for their symptoms and the remaining 9 patients had either poor left ventricular function, an obstructed mitral prosthesis, or an obstructed tricuspid prosthesis. The various groups could not be identified on clinical, radiological, or electrocardiographic features, but severe paraprosthetic regurgitation was associated with a reduced A2-OC interval

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Colour flow Doppler mapping in the assessment of prosthetic valve regurgitation.

Two hundred Carpentier-Edwards, Björk-Shiley, and Starr-Edwards prostheses in 173 patients were examined. Sixteen (16%) in the aortic and 24 (25%) in the mitral position were associated with clinical signs of regurgitation. A phased array system (Hewlett-Packard A77020A) with a 2.5 MHz duplex and 1.9 MHz continuous wave transducer was used. Colour flow mapping showed trivial transvalvar regurgi...

متن کامل

Diagnosis of prosthetic mitral valve malfunction with combined echo-phonocardiography.

Fifty-three patients were studied with combined echo-phonocardiography or phonocardiography alone following prosthetic valve replacement. In sixteen of these patients, clinical deterioration developed, and all subsequently underwent cardiac catheterization and/or surgery. Two patients came to autopsy. Included in this group of sixteen patients were five with obstructed prosthesis, six with para...

متن کامل

Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.

A 53-year-old woman who had undergone aortic valve replacement with a Starr-Edwards (S-E) valve (Model 1260) and open mitral commissurotomy 28 years previously was hospitalized with cardiac failure. Echocardiography showed mitral stenosis, mitral regurgitation, and a normally functioning S-E prosthesis. At reoperation, the mitral and aortic valves were replaced with St Jude bileaflet mechanical...

متن کامل

Analysis of dynamics of mitral Starr-Edwards valve prosthesis using reflected ultrasound.

The speed of closure of the mitral valve during diastole, as recorded by ultrasonocardiography, is reduced in patients with mitral stenosis. A pattern of movement similar to that of severe mitral stenosis is seen in recordingsfrom patients with normally functioning mitral Starr-Edwards prostheses. Simultaneous ultrasound recordings of ball and cage movements show that the prosthetic valve remai...

متن کامل

Clinical significance of multiple systolic clicks from Starr-Edwards prosthetic aortic valves.

The use of echocardiography, phonocardiography, and spectroanalysis has enhanced the ability to detect prosthetic valve dysfunction even before the onset of symptoms in many patients. Reduction in the intensity of the opening and closing clicks and the appearance of new murmurs have been the most frequently reported observations in predicting prosthetic valve dysfunction. Simultaneous echocardi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 1973