PURPOSE The purpose of this study was to determine the amount and localization of functional stresses in implants placed in two different bone types (type 3 and type 4) with three different crown heights in the atrophic posterior maxilla using finite element analysis. MATERIALS AND METHODS A three-dimensional finite element model of the posterior maxilla was created from a computerized tomography image by using the Marc 2005 (MSC Software) program. Three different crown/implant ratios (1/1, 1.5/1, 2/1) in the first molar tooth zone were modeled. Type 3 and type 4 bone quality according to the classification system of Lekholm and Zarb was created. The total oblique force of 300 N with a 30-degree angle was applied from the locations of the mesiobuccal cusp (150 N) and the distobuccal cusp (150 N) of first molar teeth. RESULTS For the implants, the highest stresses were observed around the implant neck at the crown/implant ratio of 2/1 (430.57 MPa). As the crown/implant ratio increased two times, the von Mises stresses increased at a rate of 47%. The highest tensile values exceeded the ultimate tensile strength of the cortical bone for all the designs. Also, the highest compressive values exceeded the ultimate compressive strength of the cortical bone in the 2/1 design for type 3 bone, and in the 1.5/1 and 2/1 designs for type 4 bone. As the crown/implant ratio increased from 1/1 to 2/1, the highest tensile value and the highest compressive value increased 13%. For the spongious bone, as the crown/implant ratio increased, the highest tensile value increased 42% and 85%, respectively. Tensile stresses increased at a rate of 26% in the 1/1 ratio, 30% in the 1.5/1 ratio, and 32% in the 2/1 ratio when the density of spongious bone decreased. Compression-related values also increased 34% in the 1/1 ratio, 35% in the 1.5/1 ratio, and 36% in the 2/1 ratio when the density of spongious bone decreased. CONCLUSION Compressive and tensile stresses formed mostly at the alveolar bone around the implant neck that was cortical bone. Thus, it had to be preserved during the surgical procedures. Deformation due to the stresses had great importance for the type IV spongious bone due to the increase caused by the higher crown height levels.
منابع مشابه
Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis
Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...
متن کاملتعیین توزیع تنش استخوان اطراف ایمپلنتهای فک پایین در طرحهای مختلف پروتز به هنگام Mandibular- Flexure
Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...
متن کاملEffect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis
Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...
متن کاملEffect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...
متن کاملImmediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis
Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 31 2 شماره
صفحات -
تاریخ انتشار 2016