Early Bone Response to Dual Acid-Etched and Machined Dental Implants Placed in the Posterior Maxilla: A Histologic and Histomorphometric Human Study.

نویسندگان

  • Francesco Guido Mangano
  • Jefferson Trabach Pires
  • Jamil Awad Shibli
  • Eitan Mijiritsky
  • Giovanna Iezzi
  • Adriano Piattelli
  • Carlo Mangano
چکیده

PURPOSE To compare the early bone response to implants with dual acid-etched (DAE) and machined (MA) surface, when placed in the posterior human maxilla. MATERIALS AND METHODS Fourteen patients received 2 implants in the posterior maxilla: 1 DAE and 1 MA. After 2 months, the implants were retrieved for histologic/histomorphometric evaluation. The bone-to-implant contact (BIC%), bone density in the threaded area (BDTA%), and the bone density (BD%) were calculated. The Wilcoxon matched-pairs signed rank test was used to evaluate differences (BIC%, BDTA%, and BD%) between the surfaces. RESULTS In the MA implants, a mean (±SD) BIC%, BDTA%, and BD% of 21.76 (±12.79), 28.58 (±16.91), and 21.54 (±11.67), respectively, was reported. In the DAE implants, a mean (±SD) BIC%, BDTA%, and BD% of 37.49 (±29.51), 30.59 (±21.78), and 31.60 (±18.06), respectively, was reported. Although the mean BIC% of DAE implants value was almost double than that of MA implants, no significant differences were found between the 2 groups with regard to BIC% (P = 0.198) and with regard to BDTA% (P = 0.778) and BD% (P = 0.124). CONCLUSIONS The DAE surface increased the periimplant endosseous healing properties in the native bone of the posterior maxilla.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomized, controlled histologic and histomorphometric evaluation of implants with nanometer-scale calcium phosphate added to the dual acid-etched surface in the human posterior maxilla.

BACKGROUND Placement of dental implants in the posterior maxilla has been associated with higher rates of failure that are due, in part, to the poor bone quality of this region. The purpose of the present study was the histologic and histomorphometric evaluation of the bone around a new implant surface treatment created by a deposition of nanometer-sized calcium phosphate particles added to the...

متن کامل

Sandblasted and acid-etched dental implants: a histologic study in rats.

PURPOSE Current literature has revealed that surface etching of endosseous implants can improve bone-implant contact. The aim of this study was to evaluate the differences in bone-implant contact (BIC) between sandblasted/acid-etched and machined-surface implants. MATERIALS AND METHODS Thirty-two Sprague-Dawley rats were used in this study. Two implant surfaces, Ecotek (sandblasted/ acid-etch...

متن کامل

Machined and sandblasted human dental implants retrieved after 5 years: a histologic and histomorphometric analysis of three cases.

OBJECTIVE Human retrieved implants with an intact bone-implant interface play a pivotal role in validating data obtained from in vitro studies and animal experiments. This study presents a histologic and histomorphometric analysis of peri-implant tissue reactions and of the bone-titanium interface in three machined and sandblasted dental implants retrieved after a 5-year loading period. METHO...

متن کامل

Removal torque and histomorphometric investigation of 4 different titanium surfaces: an experimental study in the rabbit tibia.

This study presents a histomorphometric and biomechanical comparison of bone response to commercially pure titanium screws with 4 different types of surface topographies placed in the tibial metaphysis of 12 rabbits. Each rabbit had 4 implants placed, 2 in each tibia. The 4 surface topographies were a machined surface, a grit-blasted surface, a plasma-sprayed surface, and an acid-etched (Osseot...

متن کامل

Risk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study

Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Implant dentistry

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2017