Development and Validation of Amisulpride in Human Plasma by HPLC Coupled with Tandem Mass Spectrometry and its Application to a Pharmacokinetic Study
نویسندگان
چکیده
In this study, authors developed a simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantification of Amisulpride in human plasma using Amisulpride-d(5) as an internal standard (IS). Chromatographic separation was performed on Zorbax Bonus-RP C18, 4.6 × 75 mm, 3.5 μm column with an isocratic mobile phase composed of 0.2% formic acid:methanol (35:65 v/v), at a flow-rate of 0.5 mL/min. Amisulpride, Amisulpride-d(5) was detected at m/z 370.1→242.1 and 375.1→242.1. The drug and the IS were extracted by a liquid-liquid extraction method. The method was validated over a linear concentration range of 2.0-2500.0 ng/mL for Amisulpride with a correlation coefficient of (r(2)) ≥ 0.9982. This method demonstrated intra- and inter-day precision within 0.9 to 1.7 and 1.5 to 2.8 % and intra- and inter-day accuracy within 98.3 to 101.5 and 96.0 to 101.0 % for Amisulpride. Amisulpride was found to be stable at 3 freeze-thaw cycles, bench top and auto sampler stability studies. The developed method was successfully applied to a pharmacokinetic study.
منابع مشابه
A quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملDevelopment and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کامل