Technical Performance of Universal and Enhanced Intraoral Imaging Rectangular Collimators.

نویسندگان

  • K Brandon Johnson
  • Sally M Mauriello
  • John B Ludlow
  • Enrique Platin
چکیده

PURPOSE The purpose of this study was to compare the number and type of technical errors between 2 rectangular collimators, time/motion effort and radiographer preference. METHODS Subjects (n=17) were recruited to expose an 18 projection full mouth series (FMX) using Tru-Align™ (enhanced) and Rinn® (universal) collimator devices. Both FMXs were exposed using photostimulable phosphor (PSP) digital sensors on a DXTTR manikin with an intraoral x-ray unit. A 5-question survey evaluated ease of device use, time required and device preference. Data were analyzed using frequencies, paired t-test, ANOVA and least squares means using a general linear model. RESULTS A lower mean number of technique errors per FMX occurred with the enhanced device (9.7) compared to the universal device (12.1). Collimator centering errors occurred 3-times more often with the universal device. The mean numbers of diagnostically unacceptable errors per FMX were similar (Universal=3.2 vs Enhanced=2.9). The least squares means adjusted model showed a statistically significant difference of errors between the 2 devices (p=0.0478) and errors by location when comparing posterior to anterior and posterior to bitewing (p<0.0001). Subjects (94%) preferred the enhanced device and found it easier to use compared to the universal device. Significantly less time was needed to expose an FMX (4 min) when using the enhanced device (p=0.0001). CONCLUSION The enhanced device enabled subjects to expose diagnostically acceptable radiographs more efficiently with fewer collimator centering errors; however, it does so with a 35% greater exposure area and a concomitant increase in patient dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mastering Basic Skills Eases Conversion to Rectangular Collimation Switching to Rectangular Collimation: First Know the Basics

During my dental training, I was taught intraoral radiography using only rectangular collimation. Once out of the dental school in 1993, I realized that not many practices used rectangular collimators. Often-heard reasons for not using a rectangular collimator are cone-cutting errors and the fact that it is easier to aim with a circular collimator. Later, during my training as a dental and maxi...

متن کامل

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

Rotational panoramic versus intraoral rectangular radiographs for evaluation of peri-implant bone loss in the anterior atrophic mandible.

PURPOSE In patients with atrophic mandibles, elevation of the floor of the mouth often prevents intraoral rectangular radiography for longitudinal follow-up studies, while extraoral techniques such as panoramic radiographs tend to produce distorted views of the interforaminal region. In this study, intraoral rectangular radiographs and panoramic radiographs were compared for their accuracy in e...

متن کامل

Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial

Objective(s): The study objective was to assess the diagnostic performance of positron emission tomography (PET) for gliomas using the novel tracer 18F-fluciclovine (anti-[18F]FACBC) and to evaluate the safety of this tracer in patients with clinically suspected gliomas.Methods: Anti-[18F]FACBC was administered to 40 patients with clinically suspected high- or low-grade gliomas, followed by PET...

متن کامل

Numerical Calculations of Short-range Wakefields of Collimators

The performance of future linear colliders are limited by the effect of short-range collimator wakefields on the beam. The beam quality is sensitive to the positioning of collimators at the end of the linac. The determination of collimator wakefields has been difficult, largely because of the scarcity of measurement data, and of the limitation of applicability of analytical results to realistic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of dental hygiene : JDH

دوره 89 4  شماره 

صفحات  -

تاریخ انتشار 2015