High-resolution imaging of the human retina with a Fourier deconvolution technique.

نویسندگان

  • David Catlin
  • Christopher Dainty
چکیده

A high-resolution retinal imaging camera is described that uses a Shack-Hartmann wave-front sensor and a Fourier deconvolution imaging technique. The operation of the camera is discussed in detail and high-resolution retinal images of the human cone mosaic are shown for a retinal patch approximately 10 arc min in diameter from two different retinal locations. The center-to-center cone spacing is shown to be approximately 2.5 microm for the retinal images recorded at 2 degrees temporal from the central fovea and approximately 4 microm for the retinal images recorded at 3 degrees temporal from the central fovea.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter

Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...

متن کامل

3d Conoscopic Holography in View of Retinal Imaging

In vivo high-resolution eye fundus imaging is a much-needed tool for early diagnosis of retinal diseases such as AMD and for the follow-up of such pathologies. One way to obtain high-resolution 3D images of the retina is to use an Adaptive Optics (AO) corrected conventional microscope (with no optical sectioning capacity) and to perform the optical sectioning a posteriori, digitally, via 3D dec...

متن کامل

High Resolution Image Reconstruction for Plenoptic Imaging Systems using System Response

Plenoptic imaging systems with a microlens array imaging the pupil at the sensor typically produce low resolution images. We introduce an inverse problem solver using the system response to obtain high resolution image reconstructions. OCIS codes: (070.0070) Fourier optics and signal processing, (110.1758) Computational imaging, (100.1830) Deconvolution, (100.3010), Image reconstruction techniq...

متن کامل

Robust Fuzzy Content Based Regularization Technique in Super Resolution Imaging

Super-resolution (SR) aims to overcome the ill-posed conditions of image acquisition. SR facilitates scene recognition from low-resolution image(s). Generally assumes that high and low resolution images share similar intrinsic geometries. Various approaches have tried to aggregate the informative details of multiple low-resolution images into a high-resolution one. In this paper, we present a n...

متن کامل

Improvements in coded aperture thermal neutron imaging

A new thermal neutron imaging system has been constructed, based on a 20-cm x 17-cm He-3 position-sensitive detector with spatial resolution better than 1 mm. New compact custom-designed position-decoding electronics are employed, as well as high-precision cadmium masks with Modified Uniformly Redundant Array patterns. Fast Fourier Transform algorithms are incorporated into the deconvolution so...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Optical Society of America. A, Optics, image science, and vision

دوره 19 8  شماره 

صفحات  -

تاریخ انتشار 2002