Modified Setting Numerical Distance Protection of Power Transmission Line in Presence Tcsc Using Iec 62850 Communication Protocol

نویسندگان

  • Mohamed ZELLAGUI
  • Abdelaziz CHAGHI
چکیده

This paper presents a study of the performance of numerical distance relay for a 400 kV electrical transmission line compensated by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Capacitor (TCSC) is connected in the middle of the transmission line and can be used in voltage mode control or reactive power injection mode, and damping of power system oscillations in high power transfer levels. IEC 61850 is a new international standard for communication networks and systems in substations that defines different message types based on their transfer time requirements. In IEC 61850 based Substation Automation systems (SAS). The effect of the TCSC on the measured impedance at the relaying point is investigated. The setting zones protection deals with the absence and presence of TCSC using IEC 61850 communication protocol for two stations i.e. Principal station and TCSC station with proposed scheme for tele-protection for studies the effects of TCSC insertion on the total impedance of a transmission line protected by MHO distance relay and the modified setting zone protection in capacitive and inductive mode for three forward zones (Z1, Z2 and Z3) have been investigated in order to prevent circuit breaker nuisance tripping to improve the performances of distance relay protection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of GCSC and TCSC Effects on MHO Distance Relay Setting in Algerian Transmission Line

This paper presents a comparative study of the performance of distance relays for transmission line high voltage (HV) 400 kV in Eastern Algerian transmission networks at Group Sonelgaz compensated by two different series Flexible AC Transmission System (FACTS) i.e. GTO Controlled Series Capacitor (GCSC) and Thyristor Controlled Series Capacitor (TCSC) connected at midpoint of an electrical tran...

متن کامل

Application MPSO Techniques for Setting Zones on Distance Protection in Presence Thyristor Controlled Series Capacitor

This paper presents the application of the Modified Particle Swarm Optimization (MPSO) technique for optimal settings zones for distance relay protect 400 kV single transmission line of Eastern Algerian transmission networks at Algerian Company of Electrical and Gas (Group Sonelgaz) compensated by Thyristor Controlled Series Capacitor (TCSC) connected at midpoint for minimized active and reacti...

متن کامل

Fault Detection and Classification in Double-Circuit Transmission Line in Presence of TCSC Using Hybrid Intelligent Method

In this paper, an effective method for fault detection and classification in a double-circuit transmission line compensated with TCSC is proposed. The mutual coupling of parallel transmission lines and presence of TCSC affect the frequency content of the input signal of a distance relay and hence fault detection and fault classification face some challenges. One of the most effective methods fo...

متن کامل

Performance analysis of FACTS devices in steady state power flow

This paper focuses on the performance analysis of FACTS devices namely SVC and TCSC in steady state power flow control. Application of Flexible AC Transmission Systems (FACTS) devices in a power system network is an efficient way for the control and transfer of bulk amount of power for long distances. The performance of SVC and TCSC for reactive power injection, real power flow, power loss and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012