Remote diagnosis of congenital heart disease in southern Arizona: comparison between tele-echocardiography and videotapes.
نویسندگان
چکیده
OBJECTIVE We report our experience with tele-echocardiography and echocardiograms recorded digitally or on videotape (recorded-echos) at The University of Arizona from August 2006 to December 2010 and compare their quality and diagnostic accuracy. MATERIALS AND METHODS Tele-echocardiograms (tele-echos) were transmitted from the Yuma Regional Medical Center to The University of Arizona via a T-1 and aT-3 line at a bandwidth of 768 kilobits per second. Recorded-echos were shipped for interpretation to The University of Arizona by overnight mail. Diagnostic accuracy was assessed by comparing tele- and recorded-echos with electrocardiograms performed by a pediatric cardiologist (PedsCard-echos). RESULTS Three hundred forty-six tele-echos in 260 patients and 455 recorded-echos in 406 patients were performed (median age, 6 and 8 days, respectively). Indications included possible congenital heart disease (CHD), patent ductus arteriosus (PDA), and persistent pulmonary hypertension of the newborn. Diagnostic categories included complex CHD, non-critical disease, PDA, and other. PedsCard-echos were available for 27% of the tele-echo and 30% of the recorded-echo patients. Comparisons between tele- and PedsCard-echo yielded no discrepancies in 12 (23%), expected resolution of condition in 26 (49%), and minor in 14 (26%). One (2%) major discrepancy was detected. Comparisons between recorded- and PedsCard-echo showed no discrepancies in 28 (40%), expected resolution of condition in 14 (20%), and minor discrepancies in 28 (40%) patients. No significant difference with respect to discrepancies was detected between tele- and recorded-echos. There was significant (p<0.01) improvement in tele- and recorded-echo study quality by 2010. CONCLUSIONS (1) Tele-echocardiography can be performed successfully with excellent accuracy. (2) The quality of tele- and recorded-echo studies improved toward the end of the analysis period. (3) Although initially tele-echo studies were more accurate than recorded-echo studies, there was no difference between these two types of studies by the fourth year of the study. (4) Both tele- and recorded-echos were indispensible in the remote diagnosis of CHD.
منابع مشابه
Comparative study of pulse oximetry, physical examination and echocardiography results in the diagnosis of congenital heart defects in neonates in the first 24 hours of life
Introduction: Congenital heart disease is the most common congenital anomaly. About 50% of Neonates with congenital heart disease are asymptomatic in the first few days of life and are not diagnosed on initial examination. Pulse oximetry is a non-invasive method that can show the percentage of oxygen saturation in the blood and congenital heart disease. Methods: This was a descriptive cross-se...
متن کاملEchocardiographic Evaluation in Neonates Suspected to Congenital Heart Disease in NICU
Background and Objective: Congenital heart disease (CHD) is the most form of cardiovascular disease in children. CHD have different presentations, from defects that progress asymptomatically to those with significant symptoms and high mortality. This study was performed to highlight the importance of signs and symptoms to diagnosis of CHD neonates. Materials & Methods: This descriptive analyt...
متن کاملThe Prevalence of Celiac Disease in Down syndrome Children with and without Congenital Heart Defects
Background The prevalence of celiac disease (CD) is remarkably varied in Down syndrome(DS)patientscompared with other diseases. This study aimed to assess celiac disease prevalence in Down syndrome children with and without congenital heart defects (CHD) and its comparison with controls. Materials and Methods This case-control study was performed at a single center on 132 participants in three...
متن کاملHeart Carcinoid Disease with Patent Foramen Ovale Treated by Mini Sternotomy
This case report was an attempt to present the importance of diagnostic echocardiography and closure of a patent foramen ovale in carcinoid heart disease. Herein, we present a case of a 48-year-old woman with a carcinoid metastasis presenting with tricuspid regurgitation, pulmonic stenosis, patent foramen ovale, and borderline left ventricular ejection fraction on an echocardiogram. Surgical in...
متن کاملComparison between M-Mode and Doppler echocardiography in diagnosis
Introduction: Patent ductus arteriosus (PDA) is the persistence of a normal fetal structure between left pulmonary artery and descending aorta. Persistence of this fetal structure beyond 10 days of life is considered abnormal. In this study we compared M-Mode and Doppler echocardiography in diagnosis of PDA in children at Aliasghar Hospital in Zahedan and Children hospital in Bandar Abbas for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Telemedicine journal and e-health : the official journal of the American Telemedicine Association
دوره 18 10 شماره
صفحات -
تاریخ انتشار 2012