Near-infrared thermal lens spectrometer based on an erbium-doped fiber amplifier and an acousto-optic tunable filter, and its application in the determination of nucleotides.
A novel spectrometer that is based on the use of the thermal lens effect for sensitive measurements of absorption in the near-IR region has been developed. In this instrument the near-IR excitation light (from 1515 to 1590 nm) was provided by an erbium-doped fiber amplifier (EDFA). An acousto-optic tunable filter (AOTF) was used to spectrally disperse the light from the EDFA. The AOTF was used ...
متن کاملRapid near-infrared fluorescence excitation-emission matrix spectroscopy for multifluorophore characterization using an acousto-optic tunable filter technique.
We report on a novel acousto-optic tunable filter (AOTF)-based near-infrared (NIR) fluorescence excitation-emission matrix (EEM) spectroscopy technique for rapid multifluorophore characterization. We implement a unique light filtering module design by using cascaded AOTFs coupled with three orthogonally oriented polarizers to effectively remove the side-ripple artifacts of AOTFs as well as by u...
متن کاملIn-flight performance and calibration of SPICAV SOIR onboard Venus Express.
Solar occultation in the infrared, part of the Spectoscopy for Investigation of Characteristics of the Atmosphere of Venus (SPICAV) instrument onboard Venus Express, combines an echelle grating spectrometer with an acousto-optic tunable filter (AOTF). It performs solar occultation measurements in the IR region at high spectral resolution. The wavelength range probed allows a detailed chemical i...
متن کاملAnalysis of the Spectral Resolution of a TeO2 Based Noncollinear Acousto-Optic Tunable Filter
The spectral resolution is a main index of evaluating the performance of the designed acousto-optic tunable filter (AOTF). In this letter, an accurate expression of the spectral resolution is presented by considering both the birefringence and the rotatory property of TeO2 crystal. The deduced expression is significant in improving the accuracy of the design of an AOTF and pushing the developme...
متن کاملOnline monitoring of urea concentration in dialysate with dual-beam Fourier-transform near-infrared spectroscopy.
The robustness of a dual-beam, optical null, Fourier-transform near-infrared (FTNIR) spectrometer was investigated by means of online, near-infrared measurements and predictions of urea concentrations in spent dialysate during hemodialysis treatment. Simple multivariate calibration using a few factors based on a small number of prepared samples provided stable and accurate predictions over a pe...