Identification and Titration of Hydro Pericardium Syndrome Virus (HPSV) by using Modified Counter-Current Immuno-Electrophoresis (MCCIE)

نویسندگان

  • Manoor Soha
  • Imtiaz Ali Khan
چکیده

A rapid, simple, and accurate Modified Counter Current Immuno-electrophoresis (MCCIE) technique was developed and compared with the Reverse Passive Heamagglutination Assay (RPHA) for the titration of HPS virus. The MCCIE test had 100% correlation with the conventional RPHA and correctly titrated 116 samples which were already titrated with RPHA. Instead of horizontal electrophoresis chamber used in counter current Immunoelectrophoresis test, a modification in Counter Current Immuno-Electrophoresis (CCIE) test was made by using 1% melted agarose gel filled in 8 cm long and 3 mm narrow U-shaped glass tubing for the detection as well as quantification & titration of HPS virus. Results of Liver samples of 116 poultry birds including 16 broilers (6 livers were from clinically positive), 50 Desi and 50 commercial layers (adult) obtained through modified counter current Immuno-electrophoresis (MCCIE) were found similar to those found though CCIE and titres obtained through MCCIE were found similar to RPHA tests. The titres in MCCIE test were expressed as appearance of hazy colored precipitation band in the twelve U-shaped tubes. All of the six clinically positive liver samples gave positive results with titres ranging from 1:32 to 1:128. Of these 6 positive, 3 samples had 1:32, 2 samples had 1:64 and 1 sample had 1:128 titres. While none of desi and commercial layer was found to be positive. The results indicated that MCCIE is simple and inexpensive test as compared to CCIE & RPHA to detect and titrate HPS virus in the infected poultry liver samples. All the HPS virus isolates from HPS infected broiler livers and adenovirus group-I obtained from NARC, Islamabad and VRI, Lahore showed MCCIE & RPHA titre (1:64) with specific HPS antibodies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of avian adenovirus type-4 causing hydro-pericardium syndrome in broilers in Karachi, Pakistan

Avian adenovirus was isolated from naturally infected birds during 1990 to 2003 in the vicinity ofKarachi, Pakistan. The virus is known to cause hydro-pericardium syndrome (HPS) in poultry. The mortalitywas recorded 20-50% in commercial broilers. Fifty field samples were collected; however, six samples wereselected for molecular studies. These isolates were grown and characterized by cell cultu...

متن کامل

SEROEPIDEMIOLOGICAL INVESTIGATION OF FASCIOLIASIS IN NORTHERN IRAN

Following an outbreak of fascioliasis in Anzali Harbor in 1988, 452 blood samples were collected using a multistage sampling method for hematological and serological studies. After determination of eosinophilia in the samples, antifasciolia antibodies in the sera were also determined using enzyme linked immuno sorbant assay (ELISA) and counter-current immuno electrophoresis (CCIE). 64.2% ...

متن کامل

Application of polymerase chain reaction in detection of egg drop syndrome (EDS) virus

  Egg drop syndrome (EDS) is caused by a hemagglutinating adenovirus which has become a major cause of lost egg production and sever economic losses in breeder and layer chicken flocks throughout the world. A PCR assay was optimized for detection of EDS virus in inoculated allantoic fluids (AFs) of duck and chicken emberyonated eggs. Two strains of EDS viruses were propagated in allantoic cavit...

متن کامل

Non-Hodgkin Lymphoma in a Child with Schimke Immuno-Osseous Dysplasia

Schimke immuno-osseous dysplasia is a rare autosomal recessive multisystem disorder characterized by steroid-resistant nephrotic syndrome, immunodeficiency, and spondyloepiphy-seal dysplasia. Mutations in SWI/SNF2 related, matrix associated, actin dependent regulator of chromatin, subfamily a-like 1 (SMARCAL1) gene are responsible for the disease. The present report describes, for the f...

متن کامل

Dynamic Modeling and Identification of The Hydro Turbine Using Field Test Data (Case Study: Abbaspour Power Plant)

In order to study the stability and fast dynamic of the power grid, modeling and identification of hydropower plant systems such as turbine, governor and excitation is required. Turbine is a mechanical device and usually identified through field tests. In this paper, the identification of the unit 8 of Abbaspour power plant is conducted. The linear and nonlinear model of the Francis turbine are...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017