Analysis of fault using microcomputer protection by symmetrical component method

نویسندگان

  • Ashish Choubey
  • Latika Pande
چکیده

To enhance power supply reliability for the user terminals in the case of the distribution system to avoid interference by the fault again, rapidly complete the automatic identification, positioning, automatic fault isolation, network reconfiguration until the resumption of supply of non-fault section, a microprocessor-based relay protection device has developed. As the fault component theory is widely used in microcomputer protection, and fault component exists in the network of fault component, it is necessary to build up the fault component network when short circuit fault emerging and to draw the current and voltage component phasor diagram at fault point. In order to understand microcomputer protection based on the symmetrical component principle, we obtained the sequence current and sequence voltage according to the concept of symmetrical component. Distribution line directly to user-oriented power supply, the reliability of its operation determines the quality and level of electricity supply. In recent decades, because of the general power of the tireless efforts of scientists and technicians, relay protection technology and equipment application level has been greatly improved, but the current domestic production of computer hardware, protection devices are still outdated systems. Software development has maintenance difficulties and short survival time. With the factory automation system interface functions weak points, the network communication cannot meet the actual requirements. Protection principle configuration and device manufacturing process to be improved

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Discrimination of Fault from Non-Fault Event in Transformer Using Concept of Symmetrical Component

In this paper a overcurrent protection using concept of symmetrical component for power transformer is presented .first we review the concept of symmetrical component. Secondly we investigate how the concept of symmetrical component can be used to improve the transformer protection scheme and how it helps to discriminate the fault and non fault events. For this an algorithm and discrimination c...

متن کامل

A Fault Diagnosis Method for Automaton based on Morphological Component Analysis and Ensemble Empirical Mode Decomposition

In the fault diagnosis of automaton, the vibration signal presents non-stationary and non-periodic, which make it difficult to extract the fault features. To solve this problem, an automaton fault diagnosis method based on morphological component analysis (MCA) and ensemble empirical mode decomposition (EEMD) was proposed. Based on the advantages of the morphological component analysis method i...

متن کامل

A Fault Diagnosis Method for Automaton Based on Morphological Component Analysis and Ensemble Empirical Mode Decomposition

In the fault diagnosis of automaton, the vibration signal presents non-stationary and non-periodic, which make it difficult to extract the fault features. To solve this problem, an automaton fault diagnosis method based on morphological component analysis (MCA) and ensemble empirical mode decomposition (EEMD) was proposed. Based on the advantages of the morphological component analysis method i...

متن کامل

اثر DVR بر بهبود کمبود و بیشبود ولتاژ سیستم توزیع در شرایط هارمونیکی (یادداشت فنی)

Today, with attention to increase in sensitive electrical equipments application in distribution networks and their susceptibility to the power quality deficiencies, the protection necessity of sensitive loads against undesirable effects of these disturbances are in focus. So, in this paper voltage sag deficiency and Dynamic Voltage Restorer (DVR) would be introduced as the most prevalent power...

متن کامل

A Practical approach for fault component network for Current and Voltage Phasor Diagram in Power Electronic Environment

In many large-scale power plants, the structure of its auxiliary power system is complex, and the coordination of its relay protections is difficult. To enhance power supply reliability for the user terminals in the case of the distribution system to avoid interference by the fault again, rapidly complete the automatic identification, positioning, automatic fault isolation, network reconfigurat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012