Intraluminal ultrasound imaging through a balloon dilation catheter in an animal model of coarctation of the aorta.

نویسندگان

  • A Rothman
  • F Ricou
  • R G Weintraub
  • R Crowley
  • R Arcangeli
  • T Shiota
  • J Zhang
  • D J Sahn
چکیده

BACKGROUND Controversy still exists over the optimal balloon size, extent of vascular disruption, and long-term results of balloon dilation therapy for coarctation of the aorta. Intravascular ultrasound imaging has been used in patients with coronary artery disease to provide further insight into the anatomy of atherosclerotic lesions and the results of angioplasty and atherectomy. Initial observations of the results of balloon dilation of coarctations with intravascular ultrasound imaging have shown prominent dissections of the inner vascular layers that are often not detected by angiography. The purpose of this study was to test a new transballoon catheter ultrasonic imaging system capable of on-line direct visualization of lumen diameter and vessel wall structure for imaging before, during, and after dilation in an acute animal model of aortic coarctation. METHODS AND RESULTS Abdominal aortic coarctations were created surgically in three 14-19-kg mongrel dogs by using Teflon gauze ties. The 6.8F ultrasound balloon catheter was placed percutaneously in the right femoral artery through a 9F sheath. Ultrasound imaging allowed measurement of the coarctation diameter, characterization of the vessel wall structure, localization of the stenosis, and placement of the midportion of the balloon at the narrowest area. Imaging through the balloon was performed through several dilations (five to eight per animal), and after balloon deflation, it provided information on postdilation diameter, intimal tears, long-segment dissections, and intramural thrombi, findings that were confirmed at postmortem examination. CONCLUSIONS The results of this study demonstrate that imaging with a new intraballoon ultrasound device is feasible during inflation to therapeutic dilation pressures; it allows visualization of the changes in diameter and vascular wall structure after serial dilations without having to recross the obstructed area. Adaptation to larger balloon sizes and lower frequencies should make this system applicable to interventional catheterizations in patients with congenital cardiac and vascular lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

BALLOON ANGIOPLASTY IN NATIVE AORTIC COARCTATION: RESULT S IN SHIRAZ AND REVIEW OF ARTICLES

Balloon angioplasty for aortic coarctation was introduced in 1979 for the fust time.1 This procedure soon became the choice treatment for restenosis of operated coarctation,2-5 but remains controversial for native (unoperated) coarctation. However, it seems to be rapidly becoming the intervention of choice for relief of unoperated coarctation as well. In this study, we evaluate the outcome ...

متن کامل

Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions. In vivo comparison to cineangiography.

Tomographic imaging techniques such as ultrasound can provide important information in the evaluation of vascular anatomy. Recent technical advances have permitted fabrication of a small (1.83 mm), phased-array, intravascular ultrasonic imaging catheter capable of continuous real-time, cross-sectional imaging of blood vessels. We used this imaging catheter to compare intraluminal ultrasound wit...

متن کامل

Balloon angioplasty with stent implantation in experimental coarctation of the aorta.

BACKGROUND Balloon angioplasty of coarctation of the aorta is an effective method of treatment but is complicated by tearing of the aortic intima, formation of aneurysms, and restenosis. Stent placement at the time of balloon dilation could prevent restenosis and could also prevent progression of intimal tears to aneurysms. The purpose of this study was to evaluate the feasibility of balloon di...

متن کامل

New Phased-Array Ultrasound Imaging Catheter in the Assessment of Vascular Dimensions

uous real-time, cross-sectional imaging of blood vessels. We used this imaging catheter to compare intraluminal ultrasound with cineangiography in the measurement of vascular dimensions in animals and to assess the intraobserver and interobserver variability of the technique. Segmental deformation of vessel anatomy was produced by stenoses created with a tissue ligature or by balloon dilation. ...

متن کامل

Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method

Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 85 6  شماره 

صفحات  -

تاریخ انتشار 1992