WE-E-BRB-07: Direct 3D Fluence Calculation from Machine Beam Parameters for VMAT Delivery Verification.

نویسندگان

  • D Yang
  • H Li
  • B Sun
  • J Tan
  • S Mutic
چکیده

PURPOSE MLC dynamic log files have been clinically used for quality assurance for years. The logged machine parameters and the derived beam 2D fluence maps can be compared to the ones obtained in the treatment plans in order to evaluate the accuracy and consistency of IMRT beam deliveries. In this study, we propose a computationally efficient method, called Direct 3D Fluence Calculation or D3DFC, to extend 2D fluence map derivation to 3D fluence volume computation. The aim is to extend dynalog-based QA from fixed-gantry IMRT to rotational-gantry VMAT. METHODS D3DFC calculates the 3D volume of photon fluence distribution directly from the machine parameters (gantry angles, jaw positions, MLC positions, collimator rotation angle, MU) contained in the dynamic log files or DICOM plans, without converting to 2D fluence maps per gantry angle in order to allow higher computation speed and accuracy. For testing, results were verified with film-in-air measurements. 3D fluence volumes computed from VMAT delivery records (with artificially introduced delivery errors) are compared to ones computed from the treatment plans to determine if these delivery errors can be identified. RESULTS D3DFC is implemented in MATLAB and supports the DICOM plans, Varian MLC dynamic logs and Varian Truebeam machine logs. Computation takes 10 to 20 seconds for a single-arc VMAT plan or delivery records. The results showed that 1 mm MLC errors can be clearly detected using delivery-to-plan fluence volume comparison. CONCLUSIONS Direct computation from machine parameters allows higher computation speed and accuracy. These advantages are useful for beam delivery verification purposes for which (slower) full patient CT based dose computation is less necessary. The calculated 3D photon fluence volume is useful to detect and visually present the VMAT delivery discrepancies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A method to reconstruct and apply 3D primary fluence for treatment delivery verification

MOTIVATION In this study, a method is reported to perform IMRT and VMAT treatment delivery verification using 3D volumetric primary beam fluences reconstructed directly from planned beam parameters and treatment delivery records. The goals of this paper are to demonstrate that 1) 3D beam fluences can be reconstructed efficiently, 2) quality assurance (QA) based on the reconstructed 3D fluences ...

متن کامل

WE-E-BRB-09: A GPU-Based Monte Carlo QA Tool for IMRT and VMAT.

PURPOSE To develop a GPU-based Monte Carlo (MC) 3D dosimetry quality assurance (QA) tool employing patient geometry and actual delivery information. METHODS First, we generate fluence maps at all beam angles from the initial treatment plan. A GPU-based MC dose engine, gDPM, is employed for the secondary dose calculation (SDC) on patient CT. This SDC is used to verify the TPS plan dose (PD) ac...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

A Generalized Strategy for 3D Dose Verification of IMRT/VMAT Using EPID-measured Transit Images

The aim in this study is to develop a generalized strategy for 3D dose verification of IMRT and VMAT planes using EPID transit images in combination with Monte Carlo (MC) simulations. An EPID-based dosimetric verification procedure was developed to convert EPID-measured transit images into 2D exit photon fluence by de-convoluting with the MC-simulated EPID response kernels. The present scatter ...

متن کامل

Performance evaluation of gated volumetric modulated arc therapy

Background: Aim of this study is to evaluate the accuracy of the gated volumetric modulated arc therapy (VMAT/RapidArc) using 2D planar dosimetry, DynaLog files and COMPASS 3D dosimetry system. Materials and Methods: Pre-treatment quality assurance of 10 gated VMAT plans was verified using 2D array and COMPASS 3D dosimetry system. Advantage of COMPASS over 2D planar is that it provides the clin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part27  شماره 

صفحات  -

تاریخ انتشار 2012