Oxygenation and blood flow in tumors treated with hydralazine: evaluation with a novel luminescence-based fiber-optic sensor.
نویسندگان
چکیده
Two optical methods were used simultaneously to evaluate the effect of a vasoactive drug hydralazine on oxygenation and blood flow in SA-1 tumors in A/J mice. A novel luminescence-based optical sensor (OxyLite instrument, Oxford Optronix, UK) was used to monitor partial pressure of oxygen (pO2) in tumors. Laser Doppler flowmetry was used to assess relative blood perfusion in tumors. Measurements were performed continuously on anesthetized mice before and after i.v. injection of hydralazine at a dose of 2.5 mg/kg. Hydralazine reduced pO2 on average by 80% minutes after injection. Our results indicate that hydralazine could be used to improve the antitumor effectiveness of hypoxic cell-specific therapies. We demonstrated that both optical methods can be used successfully to detect changes in blood perfusion and oxygenation in tumors after blood flow-modifying treatments. Some aspects of pO2 measurement with the new luminescence-based method require further investigation.
منابع مشابه
First experience with a novel luminescence-based optical sensor for measurement of oxygenation in tumors
Background. The purpose of this preliminary study was to evaluate a novel luminescence-based fiber-optic sensor (OxyLite system) for the measurement of partial pressure of oxygen (pO2) in tumors and for the detection of changes in pO2 as a function of time. The new method was used simultaneously with the laser Doppler flowmetry method for the measurement of relative tissue perfusion. Materials ...
متن کاملMeasurement of tumor oxygenation: in vivo comparison of a luminescence fiber-optic sensor and a polarographic electrode in the p22 tumor.
Hypoxia is important in tumor biology and therapy. This study compared the novel luminescence fiber-optic OxyLite sensor with the Eppendorf polarographic electrode in measuring tumor oxygenation. Using the relatively well-oxygenated P22 tumor, oxygen measurements were made with both instruments in the same individual tumors. In 24 air-breathing animals, pooled electrode pO(2) readings lay in a ...
متن کاملMeasurement of tumor oxygenation: a comparison between polarographic needle electrodes and a time-resolved luminescence-based optical sensor.
A novel oxygen sensor which does not rely on electrochemical reduction has been used to measure the oxygenation of the murine sarcoma F in a comparative study with an existing polarographic electrode that is available commercially. The prototype luminescence sensor yielded an oxygen distribution comparable with readings made using a pO2 histograph. The percentage of regions detected that had a ...
متن کاملFiber - Optic Sensing of Linear Thermal Expansion (RESEARCH NOTES)
The use of a LED fiber-optic sensor to measure displacement and linear thermal expansion is described. It has a sensitivity of about 0.6 mV/mm, a resolution of 1.25 mm, and a dynamic rang of 400 mm for displacement measurements. For thermal expansion, it shows a sensitivity of about 3.5 mV/C, and the experimental linear expansion values are in agreement with those calculated. The reported senso...
متن کاملA fiber optic sensor for measuring glucose in aqueous solutions
In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Technology and health care : official journal of the European Society for Engineering and Medicine
دوره 10 5 شماره
صفحات -
تاریخ انتشار 2002