I-123 metaiodobenzylguanidine cardiac scintigraphy in patients with an implanted permanent pacemaker.
نویسندگان
چکیده
T1 scintigraphic abnormalities have been reported in patients with an implanted permanent pacemaker, but little is known about the MIBG scintigraphic findings in such patients. This study was performed to assess the MIBG scintigraphic findings in patients with an implanted permanent pacemaker, and to test the hypothesis that imaging characteristics of MIBG scintigraphy differ according to its mode. Twelve patients (4 men and 8 women, mean age: 72.4 +/- 9.5 years), who had undergone the implantation of a permanent pacemaker for bradyarrhythmias, underwent MIBG scintigraphy. The patients were divided into VVI pacemaker and DDD pacemaker groups. The tomograms were divided into nine segments and the MIBG defect in each segment scored on a scale ranging from 0 (normal uptake) to 3 (no uptake). Total MIBG defect scores were generated by summing the scores for the nine segments in each patient. MIBG scintigraphic abnormalities were found in ten of the twelve patients. The six patients with the VVI pacemaker manifested MIBG scintigraphic abnormalities. These MIBG scintigraphic abnormalities were observed in all segments, particularly in the posterior segments. The mean total defect score of the VVI group was higher than that of the DDD group (14.8 +/- 9.8 vs 3.0 +/- 3.5, respectively p < 0.05). Therefore, we conclude that despite several limitations of the study, MIBG scintigraphic abnormalities occur in patients with implanted permanent pacemakers, and that such abnormalities are more prominent with the VVI than DDD pacemaker.
منابع مشابه
Cardiac 123I-metaiodobenzylguanidine Scintigraphy in a Patient with Familial Parkinsonism with Parkin Gene Mutation
A decreased cardiac (123)I-metaiodobenzylguanidine ((123)I-MIBG) uptake has been used as a powerful tool to identify Lewy body disease, such as idiopathic parkinson's disease (IPD). We performed cardiac (123)I-MIBG scintigraphy in patient with autosomal recessive juvenile parkinsonism (ARJP) with parkin gene mutation (PARK2). The findings showed normal cardiac (123)I-MIBG uptake. Therefore, alt...
متن کاملLife-threatening ventricular arrhythmia due to silent coronary artery spasm: usefulness of I-123 metaiodobenzylguanidine scintigraphy for detecting coronary artery spasm in the era of automated external defibrillators: a case report
INTRODUCTION Cardiac arrhythmia is sometimes life-threatening, and automated external defibrillators are presently used in some countries. Coronary artery spasm is one of the primary causes of life-threatening arrhythmia. In general, chest symptoms are key indicators of possible coronary artery spasm; however, if chest symptoms are not present, clinicians may not suspect this disease. We encoun...
متن کامل123I-MIBG Scintigraphy as a Powerful Tool to Plan an Implantable Cardioverter Defibrillator and to Assess Cardiac Resynchronization Therapy in Heart Failure Patients
Iodine-123-metaiodobenzylguanidine ((123)I-MIBG) scintigraphy is a nuclear medicine technique which describes the functional status of the cardiac sympathetic nervous system. It is well known that an autonomic dysfunction is present in heart failure setting as a neuronal uptake of norepinephrine is impaired in the failing myocardium. Reduction in sympathetic nervous function in the heart, measu...
متن کاملRisk Stratification of Sudden Cardiac Death by Evaluating Myocardial Sympathetic Nerve Activity Using Iodine-123 Metaiodobenzylguanidine Scintigraphy in Patients with Chronic Heart Failure and Dilated Cardiomyopathy
A Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) has proven the efficacy of prophylactic implantable cardioverter defibrillator (ICD) use for chronic heart failure pa‐ tients without sustained ventricular tachycardia (SVT) and a history of ventricular fibril‐ lation, not restricted in those with myocardial infarction [1]. Since ICD is an expensive device, risk stratification is required...
متن کاملIdiopathic REM Sleep Behavior Disorder: Implications for the Pathogenesis of Lewy Body Diseases
Objectives. Both results of the odor identification and cardiac (123)I-metaiodobenzylguanidine accumulation have been investigated for their potential to enhance the detection of pathogenesis resembling that of Lewy body-related α-synucleinopathies in patients clinically diagnosed as having idiopathic REM sleep behavior disorder. Methods. We performed both the Odor Stick Identification Test for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Japanese heart journal
دوره 36 5 شماره
صفحات -
تاریخ انتشار 1995