Vibrational spectroscopy of triacetone triperoxide (TATP): anharmonic fundamentals, overtones and combination bands.
نویسندگان
چکیده
The vibrational spectrum of triacetone triperoxide (TATP) is studied by the correlation-corrected vibrational self-consistent field (CC-VSCF) method which incorporates anharmonic effects. Fundamental, overtone, and combination band frequencies are obtained by using a potential based on the PM3 method and yielding the same harmonic frequencies as DFT/cc-pVDZ calculations. Fundamentals and overtones are also studied with anharmonic single-mode (without coupling) DFT/cc-pVDZ calculations. Average deviations from experiment are similar for all methods: 2.1-2.5%. Groups of degenerate vibrations form regions of numerous combination bands with low intensity: the 5600-5800 cm(-1) region contains ca. 70 overtones and combinations of CH stretches. Anharmonic interactions are analyzed.
منابع مشابه
Raman and infrared fingerprint spectroscopy of peroxide-based explosives.
A comparative study of the vibrational spectroscopy of peroxide-based explosives is presented. Triacetone triperoxide (TATP) and hexamethyl-enetriperoxide-diamine (HMTD), now commonly used by terrorists, are examined as well as other peroxide-ring structures: DADP (diacetone diperoxide); TPTP [3,3,6,6,9,9-Hexaethyl-1,2,4,5,7,8-hexaoxo-nonane (tripentanone triperoxide)]; DCypDp {6,7,13,14-Tetrao...
متن کاملDetecting a peroxide-based explosive via molecular gelation.
A convenient and portable triacetone triperoxide (TATP) sensor was developed utilizing a thiol-to-disulfide oxidation to trigger a solution-to-gel phase transition. Using this method, TATP can be detected visually without any instrumentation.
متن کاملA colorimetric sensor array for detection of triacetone triperoxide vapor.
Triacetone triperoxide (TATP), one of the most dangerous primary explosives, has emerged as an explosive of choice for terrorists in recent years. Owing to the lack of UV absorbance, fluorescence, or facile ionization, TATP is extremely difficult to detect directly. Techniques that are able to detect generally require expensive instrumentation, need extensive sample preparation, or cannot detec...
متن کاملRapid trace detection of triacetone triperoxide (TATP) by complexation reactions during desorption electrospray ionization.
Desorption electrospray ionization (DESI) mass spectrometry is used for rapid, specific and sensitive detection of trace amounts of the notorious explosive TATP present on ambient surfaces by alkali metal complexation in a simple spray technique.
متن کاملDetermination of the Vapor Density of Triacetone Triperoxide (TATP) Using a Gas Chromatography Headspace Technique
Using a GC headspace measurement technique, the vapor pressure of TATP was determined over the temperature range 12 to 60 8C. As a check on the experimental method, TNT vapor pressure was likewise computed. Values for TNT are in excellent agreement with previous published ones. For TATP the vapor pressure was found to be ~7 Pa at ambient conditions. This value translates to a factor of 10 more ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy
دوره 71 4 شماره
صفحات -
تاریخ انتشار 2008