Evaluation of two fast and easy methods for pesticide residue analysis in fatty food matrixes.
نویسندگان
چکیده
Two rapid methods of sample preparation and analysis of fatty foods (e.g., milk, eggs, and avocado) were evaluated and compared for 32 pesticide residues representing a wide range of physicochemical properties. One method, dubbed the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method for pesticide residue analysis, entailed extraction of 15 g sample with 15 mL acetonitrile (MeCN) containing 1% acetic acid followed by addition of 6 g anhydrous magnesium sulfate and 1.5 g sodium acetate. After centrifugation, 1 mL of the buffered MeCN extract underwent a cleanup step (in a technique known as dispersive solid-phase extraction) using 50 mg each of C18 and primary secondary amine sorbents plus 150 mg MgSO4. The second method incorporated a form of matrix solid-phase dispersion (MSPD), in which 0.5 g sample plus 2 g C18 and 2 g anhydrous sodium sulfate was mixed in a mortar and pestle and added above a 2 g Florisil column on a vacuum manifold. Then, 5 x 2 mL MeCN was used to elute the pesticide analytes from the sample into a collection tube, and the extract was concentrated to 0.5 mL by evaporation. Extracts in both methods were analyzed concurrently by gas chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry. The recoveries of semi-polar and polar pesticides were typically 100% in both methods (except that basic pesticides, such as thiabendazole and imazalil, were not recovered in the MSPD method), but recovery of nonpolar pesticides decreased as fat content of the sample increased. This trend was more pronounced in the QuEChERS method, in which case the most lipophilic analyte tested, hexachlorobenzene, gave 27 +/- 1% recovery (n=6) in avocado (15% fat) with a<10 ng/g limit of quantitation.
منابع مشابه
Estimation of measurement uncertainty in pesticide residue analysis.
Proficiency test results from 5 countries involving 61 separate interlaboratory proficiency tests for pesticide residues were examined in this study. A total of 24 different matrixes and 869 relative standard deviations of the mean (or median) pesticide residue concentration were statistically evaluated in relation to the Horwitz function. The aim was to determine whether or not the concentrati...
متن کاملResidue Levels and Risk Assessment of Pesticides in Pistachio Nuts in Iran
Background: Pistachio is one of the main nutrients, not only as a strategic crop but also as a main type of nut, in Iranians’ food cycle. The aim of this study was to measure the relative safety of Iranian pistachio based on the standard pesticide’s residue limits, which should be monitored and assessed in the cultivation of pistachio in order to confirm its public health. Method...
متن کاملMulti-Residue Analysis of Pesticides in Pistachio Using Gas Chromatography-Mass Spectrometry (GC/MS)
Background: Analysis of pesticide residues in food and other environmental commodities have become an essential requirement for consumers, producers, food inspectors and authorities. This study is focused on validation of an accurate, rapid and reliable method for multi-residual analysis of pesticides in pistachio as a strategic crop for export and one of the main nuts in Iranian food basket.Me...
متن کاملMulti-analyst, multi-matrix performance of the QuEChERS approach for pesticide residues in foods and feeds using HPLC/MS/MS analysis with different calibration techniques.
Three different calibration approaches were applied in HPLC/MS/MS using electrospray ionization for the determination of 14 diverse pesticide residues at different levels in a variety of food matrixes. This study was conducted as part of a 4 day training course for 17 chemists to learn the "quick, easy, cheap, effective, rugged, and safe" (QuEChERS) approach to pesticide residue analysis in foo...
متن کاملFast GC, GC-MS and sample preparation methods for pesticide residue analysis in non-fatty baby food
Possibilities and limitations of a bench top mass spectrometric detector (MSD) in selective ion monitoring mode (SIM) and electron capture detector (ECD) in fast gas chromatography (GC) with narrow bore columns of samples with complex matrices at ultra trace levels of pesticide residues were studied and compared.. Various injection systems were searched (splitless, on-column, programmable tempe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of AOAC International
دوره 88 2 شماره
صفحات -
تاریخ انتشار 2005