VASCULAR BIOLOGY Original Studies In Vivo Comparison of a Polymer-Free Biolimus A9-Eluting Stent With a Biodegradable Polymer-Based Biolimus A9 Eluting Stent and a Bare Metal Stent in Balloon Denuded and Radiated Hypercholesterolemic Rabbit Iliac Arteries

نویسندگان

  • Ron Waksman
  • Rajbabu Pakala
  • Richard Baffour
  • Rufus Seabron
  • David Hellinga
  • Rosanna Chan
  • Shih-Horng Su
  • Frank Kolodgie
  • Renu Virmani
چکیده

Objectives: To evaluate the effect of a polymer-free Biolimus A9-eluting stent [BioFreedom (BF)], compared with that of a biodegradable polymer-based Biolimus A9-eluting stent [BioMatrix Flex (BMF)] and a bare metal stent (BMS) in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries. Methods: Rabbits were fed with 1% cholesterol diet (n 5 14) for 14 days, both iliac arteries were balloon denuded and radiated, and then rabbits were switched to 0.15% cholesterol diet. After 4 weeks, BF (n 5 8), BMF (n 5 8), and BMS (n 5 8) were deployed in denuded and radiated areas. Four weeks later animals were euthanized, arterial segments were processed for morphometry. Results: The neointimal area in vessels implanted with BF stents was significantly less than that seen in vessels implanted with BMS (0.90 mm 6 0.14 vs. 1.29 mm 6 0.23, P <0.01). Percent fibrin and fibrin score were higher with BMF stents compared to BMS (P <0.03 and <0.04) and giant cell number was significantly higher with both BMF and BF stents (P < 0.01 for both). Percent endothelialization was significantly higher and % uncovered struts were lower with BMS compared to either BMF or BF stents (P < 0.05 for both). Conclusion: This study demonstrates that compared to BMS, BF stents significantly decreased neointimal hyperplasia. VC 2011 Wiley Periodicals, Inc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polymer-free biolimus a9-coated stent demonstrates more sustained intimal inhibition, improved healing, and reduced inflammation compared with a polymer-coated sirolimus-eluting cypher stent in a porcine model.

BACKGROUND Drug-eluting stents effectively reduce restenosis but may increase late thrombosis and delayed restenosis. Persistent polymer, the drug, or a combination of both could be responsible. Local delivery of Biolimus A9, a rapamycin derivative, from a polymer-free BioFreedom stent (Biosensors International) may prevent these complications. METHODS AND RESULTS We compared high-dose (HD) (...

متن کامل

Effect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction: the COMFORTABLE AMI randomized trial.

CONTEXT The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). OBJECTIVE To compare stents eluting biolimus from a biodegradable polymer with bare-metal stents in primary PCI. DESIGN, SETTING, AND PATIENTS A prospectiv...

متن کامل

Interference of drug-eluting stents with endothelium-dependent coronary vasomotion: evidence for device-specific responses.

BACKGROUND There is evidence that endothelial coverage of drug-eluting stents might be delayed or absent, a risk factor for late thrombotic events. We studied the effects of different drug-polymer-device iterations on endothelium-dependent coronary vasomotion. Systemic markers of endothelial inflammation were correlated with coronary vasomotor changes. METHODS AND RESULTS Patients with paclit...

متن کامل

Thrombogenicity and early vascular healing response in metallic biodegradable polymer-based and fully bioabsorbable drug-eluting stents.

BACKGROUND Acute thrombogenicity and re-endothelialization represent clinically relevant end points pertaining to the safety of coronary stents, which have not been compared among biodegradable polymer-based drug-eluting metallic stents and fully bioabsorbable scaffolds to date. METHODS AND RESULTS We investigated comparative outcomes with respect to acute thrombogenicity and re-endothelializ...

متن کامل

Comparison of biolimus eluted from an erodible stent coating with bare metal stents in acute ST-elevation myocardial infarction (COMFORTABLE AMI trial): rationale and design.

AIMS Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012