Closed-loop Stimulations of Hypoglossal Nerve Using Its Spontaneous Activity as the Feedback Signal
نویسندگان
چکیده
Electrical recruitment of the upper airway (UAW) muscles has been attempted as a treatment method for Obstructive Sleep Apnea (OSA) [l-61. Hypoglossal nerve (HG) and genioglossus muscle (GG) stimulations have given successful results in OSA patients [3-61. A reliable method for detection of obstructions is needed to trigger the stimulations in phase with respiration during obstructive breaths before this technique can be used clinically. In this paper, we investigate the possibility of closed-loop HG nerve stimulations using its spontaneous activity for detection of obstructions in a dog model. The activity of the HG nerve is recorded with chronically implanted nerve cuff electrodes in sleeping dogs while a force is being applied onto the submental region to collapse the airways. The increase in the phasic HG activity as a response to the submental force is used to trigger the stimulations. Closed-loop stimulations are shown to relieve the UAWs from the collapsing effect of the submental force.
منابع مشابه
Closed-Loop Compensation of the Quadrature Error in MEMS Vibratory Gyroscopes
In this paper, a simple but effective method for compensation of the quadrature error in MEMS vibratory gyroscope is provided. The proposed method does not require any change in the sensor structure, or additional circuit in the feedback path. The mathematical relations of the proposed feedback readout system were analyzed and the proposed solution assures good rejection capabilities. Based on ...
متن کاملDynamic Load Carrying Capacity of Mobile-Base Flexible-Link Manipulators: Feedback Linearization Control Approach
This paper focuses on the effects of closed- control on the calculation of the dynamic load carrying capacity (DLCC) for mobile-base flexible-link manipulators. In previously proposed methods in the literature of DLCC calculation in flexible robots, an open-loop control scheme is assumed, whereas in reality, robot control is achieved via closed loop approaches which could render the calculated ...
متن کاملAdaptive fuzzy pole placement for stabilization of non-linear systems
A new approach for pole placement of nonlinear systems using state feedback and fuzzy system is proposed. We use a new online fuzzy training method to identify and to obtain a fuzzy model for the unknown nonlinear system using only the system input and output. Then, we linearized this identified model at each sampling time to have an approximate linear time varying system. In order to stabilize...
متن کاملControl of Flexible Link Robot using a Closed Loop Input-Shaping Approach
This paper is has addressed the Single Flexible Link Robot. The dynamical model is derived using Euler-Lagrange equation and then a proper controller is designed to suppress a vibration based-on Input-Shaping (IS) method. But, IS control method is an open loop strategy. Due to the weakness of open loop control systems, a closed loop IS control system is proposed. The achieved closed loop c...
متن کاملUnilateral Recurrent Laryngeal and Hypoglossal Nerve Paralysis Following Rhinoplasty: A Case Report and review of Articles
Introduction: Injury to cranial nerves IX, X, and XII is a known complication of laryngoscopy and intubation. Here we present a patient with concurrent hypoglossal and recurrent laryngeal nerve paralysis after rhinoplasty. Case Report: The patient was a 27-year-old woman who was candidate for rhinoplastic surgery. The next morning after the operation, the patient complained of dysphonia and a s...
متن کامل