Glove perforation and contamination in primary total hip arthroplasty.
نویسندگان
چکیده
We conducted a randomised, controlled trial to determine whether changing gloves at specified intervals can reduce the incidence of glove perforation and contamination in total hip arthroplasty. A total of 50 patients were included in the study. In the study group (25 patients), gloves were changed at 20-minute intervals or prior to cementation. In the control group (25 patients), gloves were changed prior to cementation. In addition, gloves were changed in both groups whenever there was a visible puncture. Only outer gloves were investigated. Contamination was tested by impression of gloved fingers on blood agar and culture plates were subsequently incubated at 37 degrees C for 48 hours. The number of colonies and types of organisms were recorded. Glove perforation was assessed using the water test. The incidence of perforation and contamination was significantly lower in the study group compared with the control group. Changing gloves at regular intervals is an effective way to decrease the incidence of glove perforation and bacterial contamination during total hip arthroplasty.
منابع مشابه
A Cross-sectional Analysis of Glove Perforation in Primary and Revision Total Hip Arthroplasty
The number of total hip arthroplasties is ever increasing. Literature about glove perforation rates in arthroplasties in India is very scarce. The purpose of our study was to determine the incidence of glove perforation and increasing the awareness of possible glove perforations to decrease the risk of infection. We performed a prospective study in which we tested gloves worn by all scrubbed pe...
متن کاملA prospective analysis of glove perforation in primary and revision total hip and total knee arthroplasty.
Literature in regard to glove perforation rates in revision total joint arthroplasty (TJA) is scarce. Our purpose was to determine the incidence of perforation in revision TJA. Gloves from all scrubbed personnel were tested based on the American Society for Testing and Materials. A total of 3863 gloves were collected from 58 primary and 36 revision arthroplasty cases. Surgeons had a 3.7% outer-...
متن کاملStudy of Glove Perforation during Hip Replacement Arthroplasty: Its Frequency, Location, and Timing
Objective. The aim of the study was to evaluate the location, timing, and frequency of glove perforation during hip replacement arthroplasty. Methods. Gloves worn by surgical team members in 19 primary hip replacement arthroplasties were assessed. The study was of a single gloving system. All the used gloves were collected at the end of the surgery and assessed visually and by using water infla...
متن کاملThe protective effect of a cut-resistant glove liner.
We performed a prospective, randomised study comparing the rates of glove perforation using double latex gloving with or without a disposable protective glove liner (Paraderm) on 118 patients undergoing primary or revision arthroplasty of the hip or knee by one surgeon (FRH). The patients were randomly allocated into two groups: in group 1 an inner and outer pair of latex gloves were worn as do...
متن کاملIncreased awareness of glove perforation in major joint replacement. A prospective, randomised study of Regent Biogel Reveal gloves.
An intact barrier between the hands of the surgeon and the patient remains the single most important factor in protection against infection for both. Increasing the awareness of possible glove perforation without skin penetration will decrease the risk of contamination. We performed a prospective, randomised trial comparing the incidence of glove perforation using a new type of glove (Regent Bi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 87 4 شماره
صفحات -
تاریخ انتشار 2005