Analysis of Total Organic Carbon Samples Containing NaCl Using Two Oxidation Techniques

نویسنده

  • Stephen Lawson
چکیده

The concentration of organic and inorganic carbon in seawater is of considerable interest. Some Total Organic Carbon (TOC) analyzers have been designed for straightforward analysis of these waters, with special features to avoid many of the problems found with salty samples. The presence of the chloride ion (Cl) in waters being analyzed for carbon presents problems when the method uses low temperature oxidation of carbon-to-carbon dioxide. Such instruments typically use the persulfate ion with or without ultraviolet (UV) radiation. The Cl scavenges the free radicals that are the principal agents of oxidation, markedly reducing oxidation efficiency and prolonging oxidation time to an intolerable extent. Complexation of chlorine by mercury (Hg (II)) ion introduced into the reaction mixture reduces the chloride effect, but presents disposal problems for the spent reactor fluid. Further, the (Cl) is oxidized to chlorine, which can damage the instrument's detector. Therefore, the low temperature UV-persulfate oxidation TOC analyzers are typically not advised for these salt-water applications without special reagent mixtures. With High Temperature Combustion (HTC) analyzers, the chloride ion does not affect the reaction rate and chlorine gas is not formed in high concentrations; therefore, historically these analyzers have been the instrument of choice for this application. However, the sodium ion does have a devitrifying effect on quartz glassware, which worsens with increasing temperature. Sodium chloride (NaCl) also fuses onto catalyst at high temperatures, impairing oxidation efficiency, and is difficult to remove. With persulfate oxidation based TOC analyzers, sodium and other cations do not interfere with the analysis. Oxidation Technology High Temperature Combustion The HTC technique uses heat usually in the presence of a catalyst, with a stream of hydrocarbon free compressed air to oxidize organic carbon. Dissolved organics and particulate organics are expected to oxidize fully to carbon dioxide under these conditions. HTC instruments may use a variety of different catalysts including cupric oxide, cobalt oxide or titanium dioxide based platinum. HTC oxidation requires temperatures from 680°C to 1000°C depending upon the application. UV/Persulfate: Persulfate oxidation is a chemical oxidation aided by UV radiation and persulfate. This technique characteristically produces higher instrument responses versus background responses thereby yielding lower limits of detection in contrast to HTC oxidation. 2 Detection All of the oxidation techniques form CO2 from the carbon in the sample. Detection of CO2 is accomplished by either: 1) Conductivity / Membrane Conductivity allowing it to permeate a membrane into a low conductivity water stream and thereby change the water stream’s conductivity 2) Non-Dispersive Infrared purging the CO2 to an NDIR detector. Conductivity/ Membrane Conductivity: The conductivity of the sample is measured before and after it is oxidized attributing this differential measurement to the TOC of the sample. During the sample oxidization phase, CO2 and other gases are formed. The dissolved CO2 forms a weak acid, thereby changing the conductivity of the original sample proportionately to the TOC in the sample. It is assumed that only CO2 is present and, if true, the TOC of the sample may be validated by calculating by the differential measurement. Therefore, the conductivity measurement is an indirect measurement of the CO2 in the sample. The advantage of this technique is its sensitivity in pure water applications. However, the disadvantage of this technique is the fact that other ions within the sample matrix may Sales/Support: 800-874-2004 · Main: 513-229-7000 4736 Socialville Foster Rd., Mason, OH 45040 Copyright © 2008 Teledyne Tekmar Company. All Rights Reserved. www.teledynetekmar.com pass across the membrane into the pure water stream. Thus, the conductivity measurement may be influenced by the interferences. NDIR Detection: NDIR detectors use infrared (IR) energy to detect the presence of CO2. Generally, an IR beam is transmitted through the empty sample cell to establish a baseline. A second IR beam is transmitted as the sample cell fills with CO2 gas. When IR energy passes through CO2 gas, it creates a unique adsorption spectrum differentiating CO2 from other gases. Both IR beams transverse an optical filter allowing light of a predetermined wavelength (4.26μm) to reach the detector. A mass flow sensor connects pressurized front and rear cells. Changes in gas flow to the cells changes the pressure within each cell individually, which occurs as the detector fills with sample CO2 gas. This pressure difference is detected by the mass flow sensor that emits an electrical signal proportional to the magnitude of the flow. As this occurs, the instrument monitor displays a single point on a graph corresponding to the emitted electrical signal usually in millivolts (mV). This point represents the amount of CO2 inside the detector only at that particular moment. Illustrated together in Figure 1, the plotted points relate to the traditional flow-through cell bell shaped curve. As the adsorption of infrared light is measured over time, the CO2 sample result is calculated by the mathematical integration of the area underneath this curve. There is no other detection scheme that offers a more practical, interference-free method for detecting CO2 in TOC analysis than NDIR analysis. This technique measures the CO2 in the gas phase, eliminating the interference effects of other compounds that remain in the sample. Figure 1. A display of the mathematical integration of a CO2 peak or normal curve of error. Figure 2. A display of halide interference on a traditional UV/Persulfate NDIR analyzer. The Fusion’s Static Pressure Concentration NDIR Detection: Similar to flow through cell NDIR detectors, the Teledyne Tekmar Fusion’s Static Pressure Concentration (SPC) NDIR detector contains an IR light source and an optical filter. The CO2 is swept into the detector and measured. Unlike other detectors, the path flow is pressurized driving the CO2 into the detector where the exit valve is closed. Once all of CO2 is inside the detector and pressure equilibrium is reached, an electronically pulsed light source emits a dual IR beam. Each beam is filtered by a Fabry -Perot Interferometer (FPI) that filters the light beams at an absorbance wavelength that is specific for CO2 (4.26μm) and a nearby, non-absorbing wavelength used as a reference before being reflected and re-focused to the IR detector. The FPI is a micro-machined silicon chip that contains two parallel mirrors. The two parallel mirrors change distance when a voltage is applied over the chip, allowing only certain wavelengths of light to pass through to the IR detector. At the CO2 absorption wavelength, the intensity of detected light is reduced in proportion to the concentration of CO2 in the optical path. The light intensity measured at the non-absorbing wavelength serves as a baseline for comparison. The degree of light absorption in the gas, indicated by the ratio of these two signals, is proportional to the gas concentration. As stated earlier, carbon dioxide shows a unique adsorption spectrum when infrared energy passes through it, allowing the NDIR to distinguish it from other gases. By regularly measuring CO2 absorption and the reference band, the FPI can automatically compensate for light source intensity changes and loss of reflectivity of the optical sampling cell via contamination. This means that the NDIR detector itself can go for years without recalibration. Additional advantages of SPC – NDIR detection are single measurement and no associated integration errors. One measurement represents the concentration of CO2 in the cell versus multiple measurements

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

حذف کربن آلی محلول از نمونه‌های آبی توسط فرآیند اکسیداسیون فنتون

Background and Aim: Nowadays, regarding the increased human and geological activities, concentrations of toxic and carcinogenic disinfectant by-products– like Trihalomethanes -which have an organic base, in drinking water sources, has worryingly increased. Thus, the present study aimed at surveying the amount of dissolved organic carbon (doc) removed from aqueous solution by Fenton process. Mat...

متن کامل

Advanced oxidation processes against alkyl phenols in groundwater samples

Spectrophotometric examinations showed the presence of phenolic compounds in the organic residue collected from four groundwater resources located in vicinity of an oil refinery at the outskirt of Tehran. The average concentration of total phenolic compounds was about 0.38 mg.L-1 in these samples using Folin-Ciocalteu method. GC-Mass analysis disclosed that alkylphenols were the major phenolic ...

متن کامل

An automated system of sample analysis for a total carbon analyser

Standard analysis of the dissolved organic carbon (DOC) content of seawater involves the wet oxidation technique described by Menzel and Yaccaro [ 1]. In this method the sample is sealed in ampoules containing potassium persulphate. As the samples are heated in a sealed pressure vessel, the organic carbon is oxidized to CO2 which is then measured with a nondispersive infra-red analyser. Wet oxi...

متن کامل

Electrochemical Sensor for Determination of Ascorbic Acid Using a 2-Chlorobenzoyl Ferrocene/Carbon Nanotube Paste Electrode

A chemically modified carbon paste electrode with 2-chlorobenzoyl ferrocene (2CBF) and carbon nanotube (2CBFCNPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, square wave voltammetry and chronoamperometry. The diffusion coefficient (D = 1.42 × 10-6 cm2 s-1), and the kinetic parameter such as ...

متن کامل

Modification of activated carbon by cold plasma and its effect on the adsorption of toluene

Abstract Background and aims: Clean air is one of the basic needs for human health and well-being. However, along with economic growth and development, transportation, urbanization and energy consumption have also risen and provide many concerns such as air pollution, which require urgent and wide attention. Air pollution in the worldwide is considered as a risk factor for human health and one...

متن کامل

A ®eld study of the chemical weathering of ancient sedimentary organic matter

Weathering pro®les developed on organic carbon-rich black shales were studied to examine the loss and degradation of organic matter (OM) during weathering and its role in the geochemical carbon cycle. Analysis of weathered shales reveals between 60 and nearly 100% total organic carbon (TOC) loss in highly weathered samples relative to initial, unweathered TOC content. Pyrite loss coincides with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008