The influence of glide path preparation on the failure rate of WaveOne reciprocating instruments.

نویسندگان

  • C H Jonker
  • P J Van der Vyver
  • F A De Wet
چکیده

INTRODUCTION The aim of this study was to determine the influence of two different glide path preparation methods on the fracture rate of the Primary 25/08 WaveOne reciprocating instrument. Preparation times for different glide path methods and total time for root canal preparation, with and without prior glide path preparation, were also calculated. MATERIALS AND METHODS ISO 15, 0.02 taper Endo-Training-Blocks (n = 300) were selected and randomly divided into three main groups (n = 100): Group 1: no glide path (control); Group 2: glide path preparation with stainless-steel hand files; and Group 3: glide path preparation with rotary PathFiles. The time taken to prepare each glide path was recorded. The specimens in each main group were then randomly assigned into five subgroups (n=20). New Primary 25/08 WaveOne files were used for canal preparation in each subgroup. The outcome was measured by recording how many simulated canals could be shaped with one WaveOne reciprocating file in each subgroup before instrument breakage occurred. The average time it took to prepare each of the simulated canals was calculated and recorded. The data were collected and statistically analysed using the ANOVA / Bonferroni test. RESULTS Glide path preparation with PathFiles was significantly faster than with hand files (P<0.001). After the glide path preparation had been performed with PathFiles, a greater number of simulated canals could be prepared before failure of the WaveOne file (P<0.001). Root canal preparation time was significantly shorter (P<0.001) when an initial glide path had been prepared with PathFiles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Glide Path on the Centering Ability and Preparation Time of Two Reciprocating Instruments.

INTRODUCTION The aim of this in vitro study was to evaluate the effects of establishing glide path on the centering ability and preparation time of two single-file reciprocating systems in mesial root canals of mandibular molars. METHODS AND MATERIALS Sixty extracted mandibular molars with curvatures of 25-39 degrees and separate foramina for the mesiobuccal and mesiolingual canals, were divi...

متن کامل

Root canal anatomy preservation of WaveOne reciprocating files with or without glide path.

INTRODUCTION This study evaluated the influence of glide path on canal curvature and axis modification after instrumentation with WaveOne Primary reciprocating files. METHODS Thirty ISO 15, 0.02 taper Endo Training Blocks were used. In group 1, glide path was created with PathFile 1, 2, and 3 at working length, whereas in group 2, glide path was not performed. In both groups, canals were shap...

متن کامل

Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro

Introduction Endodontic instruments are developed to provide a better cleaning of the root canal system and reduce its risk of fracture. The aim of this study was to evaluate the instrumentation time and cyclic fatigue resistance of WaveOne Gold, ProDesign R and ProDesign Logic files. Methods and Materials Thirty Nickel-titanium (NiTi) rotary instruments were divided into 3 groups (n=10). Pro...

متن کامل

Comparison of the Shaping Ability of WaveOne Reciprocating Files with or without Glide Path in Simulated Curved S-shaped Root Canals

OBJECTIVES The aim was to compare the shaping ability of WaveOne reciprocating files with or without glide path in simulated curved S-shaped root canals. MATERIALS AND METHODS Forty ISO #15, 0.02 taper, clear resin Endo Training Bloc-S blocks were studied. The simulated curved S-shaped canals were dyed using ink, preinstrumentation images were scanned, and resin blocks were prepared and divid...

متن کامل

Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations

This report introduces a novel technique that allows a safe and predictable canal negotiation, creation of a glide path and canal preparation with reciprocating nickel-titanium or stainless steel engine-driven instruments in canals where the use of rotary and the newly developed reciprocating instruments is contraindicated. In this novel technique, the instruments are used in reciprocating moti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • SADJ : journal of the South African Dental Association = tydskrif van die Suid-Afrikaanse Tandheelkundige Vereniging

دوره 69 6  شماره 

صفحات  -

تاریخ انتشار 2014